54
55
Wall mount Signal Tower Instruction Manual
8. Operation
Control Command
②
Detailed motion control
・
Signal Tower: "Tier 1: Red, Flashing (slow)", "Tier 2: Red, Flashing (slow)", "Tier 3: Cyan, Flashing (slow)",
"Tier 4: Purple, Flashing (slow)"
・
Buzzer: When emit buzzer with "Pattern 7"
Transaction
ID
Protocol
ID
Field
Length
Unit ID
Function
Code
00H 00H
00H 00H
00H 1DH
00H
10H
Data
Start
Address
*1
Number of
Registers
*2
Number of
bytes
*3
Register12 Register13 Register14 Register15 Register16 Register17
00H 0BH
00H 0BH
16H
01H 01H
01H 01H
01H 05H
01H 07H
00H 00H
01H 01H
Data
Register18 Register19 Register20 Register21 Register22
01H 07H
00H 00H
00H 00H
00H 00H
00H 00H
*1 To control register addresses, specify "-1" of the start register address.
*2 Specify the number of registers to send.
*3 Specify the number of bytes in the register to send.
Response Command
②
Transaction
ID
Protocol
ID
Field
Length
Unit ID
Function
Code
Data
Start
Address
Number of
Registers
00H 00H
00H 00H
00H 06H
00H
10H
00H 0BH
00H 0BH