8. Operation
8. How to Use
8.1.
PNS Commands
・
By sending PNS commands from your computer, you can do things like control this product or get its status.
・
For the protocol, select either "TCP" or "UDP".
・
You can use communication port numbers 10000 to 65535.
●
Communication Protocols
Protocol
Port Number
TCP
10000 to 65535
UDP
Point
●
Set up PNS command settings in the "Command Configuration" screen. "7.6. Setting Up Command Reception
●
Using PNS command, you can create up to 8 simultaneous connections.
●
Commands You Can Execute
ID
Command
Overview
S (53H)
Signal Tower motion control
・
Controls tier 1 to 4 of the Signal Tower by command with colors set on
the Web screen.
・
Controls the buzzer with commands
D (44H)
Detailed motion control
(flashing all tiers)
・
Controls all tiers by specifying color for the tier 1 to 4 of the Signal Tower
with commands.
・
Controls the buzzer with commands
F (46H)
Detailed motion control
(flashing individual)
・
Individually controls tier 1 to 4 of the Signal Tower by specifying color for
each tier with commands.
・
Controls the buzzer with commands
C (43H)
Clear
Turns off the Signal Tower and stops the buzzer.
G (47H)
Get Status
Gets the status of this product.
E (45H)
Get Status Details
Gets details about the status of this product, including color information.
V (56H)
Buzzer volume setting
Set up the volume of the buzzer.