CLEARANCE AND POSITIONING AROUND THE RANGE
•
This equipment must be installed adjacent to non-combustible surfaces only with a minimum spacing of 6” from all sides. This
equipment must be 6” from other equipment. The equipment must have the 4” legs or casters installed and be placed on a non-
combustible surface.
•
For a range with casters installed, the gas connection shall be made with a connector that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69/CSA 6.16 and a quick-disconnect device that complies with the Standard
for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.4/CSA 6.9. When installing the oven with casters and quick-
disconnect hose, adequate means must be provided to limit the movement of the oven without depending on the connector and
the quick disconnect device or its associated piping to limit the oven movement. Restraining cables may be attached to the
vertical portion of the base frame in the rear of the oven.
AIR SUPPLY AND VENTILATION
•
The area in front and around the range must be kept clear to avoid any obstruction of the flow of combustion and ventilation air.
•
Adequate clearance must be always maintained in front of and at the sides of the equipment for servicing and proper ventilation.
TO INSTALL
1.
Level the range with a level gauge. The height can be adjusted by the adjustable feet. The range should not sway or tilt during
operation. Units that are not level will experience operational problems.
2.
The mounting position should be well-ventilated with proper hood exhaust system.
3.
Codes require that a gas shut off valve should be installed upstream the device where it is easily reached during operation.
4.
Make sure you are using the correct gas supply that is specified for this model. If the gas supply is not intended for this model,
do not proceed with installation.
5.
This range is applicable to low pressure regulating valves only. High pressure regulating valves and medium pressure
regulating valves are not to be used.
6.
Check to make sure the connection pipe to the unit has no leaks and that all connections and pipe joint compound used are resistant to
the action of propane gases.
7.
A pressure regulator must be installed with this unit. Ensure that the regulator type agrees with the rating plate gas supply. The regulator
must be upright after installation. If regulator is not level during operation, performance problems may result.
8.
After connecting the appliance to the gas system, check for leaks at joints and pipe fittings; to do so, use soapy water or a
leak detector spray.
9.
Check the gas supply pressure after installation.
10.
Gas supply pressure can be measured with a liquid-filled pressure gauge (e.g., a U-shaped pressure gauge, minimum scale
division 0.1mbar) or a digital gauge. Procedure as follows:
•
Ensure gas is turned off
•
Remove the panel and unscrew the screw on the pressure port
•
Place the pressure gauge
•
Start up the appliance by following the instructions in this owner’s manual
•
Check supply pressure. Pressure must agree with rating plate requirement when the unit is in full operation
•
After the check, turn off gas and remove the pressure gauge
•
Replace the sealing screw