background image

March 2016

Problem

Possible Causes

Solution

Griddle not lighting

Main gas line is closed

Open valve

Griddle not lighting

Quick disconnect not inserted all 
the way

Check quick disconnect and 

make sure it is fully inserted into 
female coupling

Griddle not lighting

Pilot is not lit

Ignite pilot light

Griddle not lighting

Cause Unknown

Call for service

Problem

Possible Causes

Solution

Pilot light not staying lit

Flame is too low

Adjust pilot light 

fl

 ame height

Pilot light not staying lit

Pilot tube clogged

Replace pilot tube and call for 

service

Problem

Possible Causes

Solution

Strong smell of gas in cooking area

Main gas line leak

Turn off main gas valve and DO 

NOT LIGHT FLAME, ignite any-
thing or turn/switch on anything 
electrical.  

Strong smell of gas in cooking area

One or more of the pilots may be 

out or burner knob turned on

Check to see if burners and 

pilots are lit.  If not, turn off all 
burner valves and main gas 
valve and wait for excess gas to 
dissipate.  Re-attempt to light 
pilots after allowing excess gas 
to clear

Problem

Possible Causes

Solution

Cooking surface is heating up 

slowly

Carbon buildup on griddle surface

Clean griddle surface

Cooking surface is heating up 

slowly

Cause unknown

Call for Service

TROUBLESHOOTING

Summary of Contents for PLATINUM

Page 1: ...rding your unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may void the warran...

Page 2: ...his altitude please contact the manufacturer Installation of this unit should conform to provisions of gas safety installation and usage This device should be kept a minimum clearance of 4 away from n...

Page 3: ...area in front and around the equipment must be kept clear to avoid any obstruction of the flow of combustion and ventilation air Adequate clearance must be maintained at all times in front of and at...

Page 4: ...t all pilots 3 The pilot burner must be lit at the end of the tube Hold an ignition source through the pilot light hole D in the front panel at the pilot tube When the flame is established remove igni...

Page 5: ...s required to put the unit in service Or if thermostatically controlled simply set to the desired temperature Do not permit fans to blow directly at the unit Whenever possible avoid open windows next...

Page 6: ...locates with corrosive substance 5 Clean the dirt on the burners and baffle regularly 6 Do not modify the ventilation volume needed during combustion 7 Accumulation of the iron substance e g Material...

Page 7: ...t tube and call for service Problem Possible Causes Solution Strong smell of gas in cooking area Main gas line leak Turn off main gas valve and DO NOT LIGHT FLAME ignite any thing or turn switch on an...

Page 8: ...March 2016 Parts Diagram for the Gas Griddles...

Page 9: ...VALVE 14 GAS INLET PIPE 15 FIXED PLATE BURNER 16 RIGHT SIDE PANEL EXTERNAL HOUSING 17 RIGHT SIDE PANEL INTERNAL HOUSING 18 LOWER FRONT BEAM 19 FRONT PANEL 20 FRONT HEAT SHIELD 21 OIL TRAY 22 RIGHT GUI...

Page 10: ...lic synthetic parts that may need to be replaced due to normal usage wear or lack of preventative maintenance This warranty covers products shipped into the 48 contiguous United States Hawaii and metr...

Reviews: