background image

2

TABLE OF CONTENTS

Overview 

         3

  

Control 

Panel 

        4

Set 

Up/Test         5

Choosing the Hand to be Tested  

 

 

 

 

5

Changing 

the 

Number 

of 

Trials 

     6

Selecting 

Pounds 

or 

Kilograms 

     6

Adjusting 

Grip 

Position 

      7

Installing/Replacing 

Batteries 

     7

Performing Grip Strength Measurements   

 

 

8

Recording Grip Strength Measurements   

 

 

9

Calculations 

        9

Normative 

Grip 

Strength 

Data 

     10

Calibration         11

Care 

and 

Storage        11

Service/Warranty        11

Summary of Contents for Jamar Smart

Page 1: ...Jamar Smart Hand Dynamometer FROM PATTERSON MEDICAL USER S GUIDE Download the Free App...

Page 2: ...ing the Number of Trials 6 Selecting Pounds or Kilograms 6 Adjusting Grip Position 7 Installing Replacing Batteries 7 Performing Grip Strength Measurements 8 Recording Grip Strength Measurements 9 Cal...

Page 3: ...f the same test protocol is used each time Up to 5 tests trials can be conducted with each hand without reset AVERAGE STANDARD DEVIATION and COEFFICIENT OF VARIATION are automatically calcu lated Hand...

Page 4: ...y to start a new test or if a mistake is made during the test Select number of repeats and supports multiple hand rapid exchange testing Automatic calculations of AVERAGE STANDARD DEVIATION and COEFFI...

Page 5: ...and with three 3 repeats CHOOSING THE HAND TO BE TESTED Press the RESET key to clear any test which might be in progress Then press the SELECT TEST key to step through the available choices Press SELE...

Page 6: ...hand selection and number of grip repeats to see how these functions work Once test protocol is changed the Jamar Smart Hand Dynamometer retains the current protocol until changed NOTE If the batteri...

Page 7: ...nt on the lower part of the handle helps prevent the handle from separating from the shaft during normal use INSTALLING AND REPLACING BATTERIES Turn the instrument so the Key Pad Operator faces front...

Page 8: ...he rear of the instrument and the fingers curl around the adjustable grip at the front of the instrument 7 Press the TEST key to begin the test Under the present test protocol start with the first tes...

Page 9: ...he test results stored in the Jamar Smart Hand Dynamometer All the test and calculation results can be viewed on the display by repeatedly pressing the TEST key All results will be displayed in the se...

Page 10: ...20 8 23 74 5 13 9 54 8 10 4 33 8 6 3 L 110 5 16 2 63 5 12 2 50 1 7 3 28 8 5 5 30 34 R 121 8 22 4 78 7 19 2 55 2 10 2 35 7 8 7 L 110 4 21 7 68 17 7 50 1 9 8 30 8 8 0 35 39 R 119 7 24 74 1 10 8 54 3 10...

Page 11: ...ide reasonable protection against harmful interfer ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Page 12: ...e present test protocol start with the first test trial and the number 1 will appear and flash at the top of the display indicating that the first test for the chosen hand is ready Have the patient sq...

Reviews: