EN
153
Troubleshooting
Problem
Cause
Remedy
Compressor doesn‘t
work
No power supply
Check cable, power plug, fuse
and power outlet
Power supply too low
Avoid too long extension cords
Outdoor temperature too low
Do not run compressor at out-
door temperatures below +5 °C
Oil level too low
Add oil
Motor overheated
Let motor cool down. Remove
overheating cause if possible.
Press the overload switch
15
Compressor runs, but
generates no pressure.
Safety valve leaky
Contact service
Sealing is broken
Check sealings. Have sealings
replaced by your HORNBACH
store
Drain screw for condensation
water leaky
Tighten screw. Check sealing of
drain screw. Replace sealing if
necessary
Compressor runs, pres-
sure is shown at the
pressure gauge, but
tools don't run.
Hose connection leaky
Check compressed-air hose
and tools, replace if necessary
Fast coupling leaky
Contact service
Pressure is set too low at the
pressure regulator
Turn pressure regulator
Warning!
Service work on the safety valve and on all other pressure parts must be
performed only by qualified service.