GB
- 146 -
11. Troubleshooting guide
Faults
Cause
Remedy
Motor fails to
start up
- No mains voltage
- Pump rotor blocked
-thermostat switched
o
ff
- Check voltage
- Dismantle and clean
pump
No intake
- Intake valve not in wa-
ter
- Pump chamber without
water connection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve)
blocked
- Max. suction height ex-
ceeded
- Immerse intake valve in
water
- Fill water into intake
- Make sure intake line is
close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate
delivery rate
- Suction height too high
- Strainer dirty
- Water level falling ra-
pidly
- Pump performance
diminishedby contami-
nants part
- Check suction height
- Clean strainer
- Place the suction hose
at a deeper level
- Clean pump and repla-
ce wearing
Thermostat
switches
pump o
ff
- Motor overloaded - fric-
tion caused by foreign
substances too high
- Dismantle and clean
pump. Prevent intake of
foreign substances (
fi
l-
ter)
Anl_PE_GP_650_SPK7.indb 146
Anl_PE_GP_650_SPK7.indb 146
08.10.15 11:14
08.10.15 11:14
Summary of Contents for PE-GP 650
Page 3: ...3 Anl_PE_GP_650_SPK7 indb 3 Anl_PE_GP_650_SPK7 indb 3 08 10 15 11 13 08 10 15 11 13...
Page 4: ...4 Anl_PE_GP_650_SPK7 indb 4 Anl_PE_GP_650_SPK7 indb 4 08 10 15 11 13 08 10 15 11 13...
Page 150: ...150 Anl_PE_GP_650_SPK7 indb 150 Anl_PE_GP_650_SPK7 indb 150 08 10 15 11 14 08 10 15 11 14...
Page 151: ...151 Anl_PE_GP_650_SPK7 indb 151 Anl_PE_GP_650_SPK7 indb 151 08 10 15 11 14 08 10 15 11 14...
Page 152: ...152 Anl_PE_GP_650_SPK7 indb 152 Anl_PE_GP_650_SPK7 indb 152 08 10 15 11 14 08 10 15 11 14...
Page 153: ...153 Anl_PE_GP_650_SPK7 indb 153 Anl_PE_GP_650_SPK7 indb 153 08 10 15 11 14 08 10 15 11 14...