GB
- 161 -
5.4 Electrical connections
•
Connect the appliance to a 230 V ~ 50 Hz socket-outlet with
earthing contact. Minimum fuse 10 ampere.
•
A built-in thermostat protects the motor from overloading and blo-
cking. The pump is switched off automatically by the thermostat if
overheating occurs and is switched on again automatically after
cooling.
6. Operation
•
Install the equipment on a solid and level surface.
•
Fill the pump housing with water via the water filler screw (7). Fil-
ling the intake line will accelerate the priming process.
•
All the shut-off devices in the discharge line (spray nozzle, valves
etc.) must be fully opened during intake in order to permit all air to
escape from the intake line.
•
Connect the mains cable.
•
Switch on the equipment with the power switch (4) - water can be
suctioned in for up to 5 minutes (maximum suction height).
•
After finishing the work, switch off the equipment with the power
switch (4).
The
fl
ow switch cannot be adjusted or switched, it is fully automatic.
There are only 3 LEDs (Fig. 3 / Item 8) to indicate its operating status.
Green LED:
The
fl
ow switch is connected to the power supply
Yellow LED:
The
fl
ow switch has tripped, the socket (Fig. 2 / Item 2) is live.
Red LED:
The
fl
ow switch has detected a fault
Anl_PE_HWA_650_SPK7.indb 161
Anl_PE_HWA_650_SPK7.indb 161
26.11.15 14:21
26.11.15 14:21