4.0 INSTA L L AT I O N
Once the Model 1045 is properly configured, it is ready to connect
to your system. This section tells you how to properly connect the
Model 1045 to the twisted pair, RS-232 and V.35 interfaces.
4.1 CONNECTION TO THE TWISTED PAIR INTERFACE
The Model 1045 supports communication between two RS-232
devices or two V.35 devices at distances to 6 miles and data rates to 64
Kbps. There are two essential requirements for installing the Model
1045:
1.
These units work in
pairs. Therefore, you must have one Model
1045 (or a compatible model) at each end of a two twisted pair
interface.
2.
To function properly, the Model 1045 needs two twisted pairs of
metallic wire. These twisted pairs must be
unconditioned, dry,
metallic wire, between 19 and 26 AWG (the higher number gauges
may limit distance somewhat). Standard dial-up telephone circuits,
or leased circuits that run through signal equalization equipment, or
standard, flat modular telephone type cable, are
not acceptable.
For your convenience, the Model 1045 is available with two
different twisted pair interfaces: RJ-11 jack and RJ-45 jack.
4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45
The RJ-11 and RJ-45 connectors on the Model 1045's twisted pair
interface are pre-wired for a standard TELCO wiring environment (see
Figure 5). The signal/pin relationships are shown on the table on the
following page:
9
Figure 5. Standard AT&T color codes
1 - Blue
2 - Yellow
3 - Green
4 - Red
5 - Black
6 - White
1 - Blue
2 - Orange
3 - Black
4 - Red
5 - Green
6 - Yellow
7 - Brown
8 - Slate
RJ-11
SIGNAL
RJ-45
SIGNAL
1...................GND
†
1 .................N/C
2...................RCV
2 .................GND
†
3...................XMT
3 .................RCV
4...................XMT
4 .................XMT
5...................RCV
5 .................XMT
6...................GND
†
6 .................RCV
7 .................GND
†
8 .................N/C
†
Connection to ground is optional
When connecting two Model 1045s, it is necessary to use a twisted
pair “crossover” cable. The diagram below shows how a crossover
cable should be constructed for an environment where both Model
1045s use a 6-wire RJ-11 connector. Similar logic should be followed
when using RJ-45 connectors or a combination of the two.
SIGNAL
PIN#
PIN#
SIGNAL
GND
†
1
6.......................GND
†
RCV
2
4.......................XMT
XMT
3
5.......................RCV
XMT
4
2.......................RCV
RCV
5
3.......................XMT
GND
†
6
1.......................GND
†
†
Connection to ground is optional
‡
Standard color codes—yours may be different
4.2 CONNECTION TO THE RS-232 AND V. 35 INTERFACES
Once you have connected the twisted pair wires correctly, simply
plug the Model 1045 directly into the DB-25 port of the RS-232 or V.35
device. After doing so, remember to insert and tighten the two captive
connector screws.
4.2.1 CONNECTION TO A “DTE” DEVICE
The Model 1045 is wired as a DCE, and therefore “wants” to plug
into a DTE such as a terminal, PC or host. A direct connection to the
RS-232 or V.35 DTE port is most desirable. If you must use a cable to
connect the Model 1045 to the DTE port, make sure it is a
straight
through cable of the shortest possible length—we recommend 6 feet or
less.
10
Summary of Contents for 1045