If the remote BER test indicates that errors 

are present, and

the local analog loopback/BER tests showed that both Model
1045RCs were functioning properly, this suggests a problem
with the twisted pair communication line connecting the two
modems.  A common problem is improper crossing of the
pairs.  Also, verify that the modular connections are pinned
properly, and the twisted pair line has continuity.  If you still
have errors, call Technical Support at (301) 975-1007.

5.2.3  USING THE V.52 BER TEST INDEPENDENTLY

The Model 1045RC's V.52 BER test can be used independent of the

V.54 loopback tests.  This requires two operators: one to initiate and
monitor the test at both the local and the remote Model 1045RC.  To
use the V.52 BER test by itself, both operators should simultaneously
follow these steps:

1.

Locate the lower of the two toggle switches on the front panel
of the Model 1045RC and move it to the right.  This will
activate the V.52 BER test mode and transmit a “511” test
pattern to the other unit.  If any errors are present, the
receiving modem’s red “Error” LED will blink sporadically.
Note:  For this independent test to function, the “511” switch on
both Model 1045RCs must be turned on. 

2.

If the test indicates no errors are present, move the V.52
toggle switch to the left, thus activating the “511/E” test with
errors present.  If the test is working properly, the receiving
modem’s red “Error” LED will glow.  A successful “511/E” test
will confirm that the link is in place, and that the Model
1045RC’s built-in “511” generator and detector are working
properly.

19

APPENDIX A

1045RC SPECIFICATIONS

Transmission Format:  

Synchronous or asynchronous, 
2-wire or 4-wire

Internal Interface:

Connection to Model 1000R16 rack 
chassis via 50 pin male card edge

External Interface:

DB-25 female (RS-232), M/34 female (V.35)
RJ-11 or RJ-45 (line)

Transmission Line: 

2-wire or 4-wire unshielded twisted pair 
(UTP), 19-24 AWG 

Data Rates:  

32, 56, 64 Kbps

Clocking:

Internal, external or receive recover

RTS/CTS Delay:

No delay, 7mS, 53mS

Controls:

Carrier constantly “ON” or “controlled by 
RTS”

Indicators: 

Bi-color LED indicators for TD, RD, RTS &
DCD; single LED indicators for Power, Test 
and Error

Diagnostics:  

V.52 compliant bit error rate pattern;  V.54 
compliant— Local Analog Loopback and 
Remote Digital Loopback, activated by front 
panel switch or via terminal interface

Transformer Isolation:

1500 V RMS

Surge Protection:

Silicon Avalanche Diodes

Temperature:

0-50°C / 32-122°F

Humidity:

4-95%, noncondensing

Dimensions:  

0.95”w x 3.1”h x 5.4”l

20

Summary of Contents for 1045RC

Page 1: ...Powered High Speed Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1045RC B Doc 054051UB Revised 3 14 97 C E R T I F I E D An IS...

Page 2: ...ar installation If the Model 1045RC does cause interference to radio or television reception which can be determined by turning the power off or removing the card the user is encouraged to try to corr...

Page 3: ...iode surge suppressors The Model 1045RC is designed to mount in Patton s 2U high 19 rack chassis This 16 card chassis has a switchable 120 240 VAC power supply optional 48 VDC and mounts cards in a mi...

Page 4: ...peration in switched carrier multipoint and or hardware handshaking applications S1 7 Setting Off Constantly on On Controlled by RTS S1 8 V 52 and V 54 Diagnostic Test To reset the V 54 circuit set sw...

Page 5: ...ng mode S2 6 Setting On Asynchronous Off Synchronous Note in asynchronous mode the Clock Source must be set to Internal S1 5 On S1 6 On 7 S2 7 RS 232 V 35 Initiation of Local Analog Loopback Test The...

Page 6: ...ward the front of the PC board 9 3 2 REAR CARD CONFIGURATION The Model 1045RC has four rear interface card options DB 25 RJ 11 DB 25 RJ 45 M 34 RJ 11 and M 34 RJ 45 see Figure 5 below Each of these op...

Page 7: ...ignal Ground and frame ground In the open position pin 1 or pin B is lifted from frame ground JB4 Position 1 2 SGND DB 25 pin 7 or M 34 pin B and FRGND Connected Position 2 3 SGND DB 25 pin 7 or M 34...

Page 8: ...lled cards 4 2 INSTALLING THE MODEL 1045RC INTO THE CHASSIS The Model 1045RC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plug into each other by way of...

Page 9: ...ment are NOT acceptable For further information about acceptable wire grades please refer to the diagram in appendix B Point to Point Twisted Pair Connection The 6 position RJ 11 and 8 position RJ 45...

Page 10: ...LED will blink sporadically 17 4 If the BER test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with periodic errors If the test is working pro...

Page 11: ...ch on both Model 1045RCs must be turned on 2 If the test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with errors present If the test is worki...

Page 12: ...he above data rate distance table as a general guideline only 21 APPENDIX C MODEL 1045RC FACTORY REPLACEMENT PARTS The Patton Model 1045RC rack system features interchangeable rear cards power cords f...

Page 13: ...m 1045RC 9 Receive Clock B From 1045RC 11 External Clock B To 1045RC 12 Transmit Clock B From 1045RC To 1045RC Data Term Ready DTR 20 DIRECTION CCITT V 35 EIA 530 INTERFACE DB 25 DIRECTION To 1045RC E...

Reviews: