Test Mode options 2,3,7,8 and 9 require the 1092RC to be in Data
Mode with the remote 1092RC. The Model 1092RC Test Modes are
described below:
OFF
Terminates all tests
511
Initiates the built-in test pattern generator
and detector.
511 with Errors
Initiates the built-in test pattern generator
and detector. The test pattern generator
also injects intentional errors approximately
once per second.
Local Line Loop
Initiates the Local Line Loop test and starts
and 511
the internal 511 generator and detector.
Local Line Loop
Initiates the Local Line Loop test and starts
and 511 w/errors
the internal 511 generator and detector. In
this test, the 511 pattern generator injects
intentional errors into the data stream.
Remote Digital
Initiates the Remote Digital Loopback test.
Loop
Any data sent to the remote 1092RC is
returned to the originating device.
Remote Digital
Initiates the Remote Digital Loopback test
Loop and 511
and starts the internal 511 generator and
detectors.
Remote Digital
Initiates the Remote Digital Loopback test
Loop and
and starts the 511test patterns. In this test
511 with errors
the 511 pattern generator will inject initial
errors into the data stream.
The Modem Status Screen is displayed upon initiating a test. A
511 error counter is displayed to indicate errors. Press the ‘C’ key to
clear the counter and redisplay the Modem Status Screen. Pressing
‘ESC’ returns you to the Test Mode Menu.
18
3.2.2 Configuring the Remote 1092RC
To configure the remote 1092RC, make a selection from the
following REMOTE UNIT CONFIGURATION MAIN MENU. To return to
the LOCAL 1092RC MAIN MENU screen, press [ESC] and refer to
Section 3.2.1
.
REMOTE MAIN MENU Option 1: Display Remote Unit Configuration
Select Option 1 to display the configuration of various parameters in
the remote Model 1092RC.
19
REMOTE UNIT CONFIGURATION
MAIN MENU
1. Display Remote Unit Configuration
2. Setup Remote Unit Configuration
3. Display Remote Modem Status
4. Select Hardware /Software Control
5. Restart Remote Unit
REMOTE CONFIGURATION
CONFIGURATION DISPLAY MENU
1. Display Configuration of:
DSR during Local Line Loop
Response to Remote Digital Loop
Clock Mode
2. Display Configuration of:
Configuration Control
DTE Rate
3. Display Configuration of:
DTE Controlled Local Line Loop
DTE Controlled Remote Digital Loop
Summary of Contents for 1092RC
Page 3: ......
Page 5: ......
Page 7: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 31: ......
Page 33: ......
Page 35: ......
Page 37: ......
Page 39: ......
Page 40: ......