background image

11

12

5.2.3  USING THE V.52 BER TEST INDEPENDENTLY

The V.52 BER test can be used independently of the V.54 loop-

back tests. This requires two operators: one to initiate and monitor the
test at the local Model 1140A, and one at the remote Model 1140A. To
use the V.52 BER test by itself, both operators should simultaneously
follow these steps:

1. Locate the “511/511E” toggle switch on the front panel of the

1140A and move it DOWN. This activates the V.52 BER test mode and
transmits a “511” test pattern to the other unit. If any errors are pres-
ent, the receiving modem’s red “Error” LED will blink sporadically.
Note: For this test to function, the “511” switch on both Model 1140As
must be on.

2. If the test indicates no errors are present, move the V.52 toggle

switch UP, activating the “511/E” test with errors present. If the test is
working properly, the receiving modem's red “Error” LED will glow. A
successful “511/E” test will confirm that the link is in place, and that the
Model 1140A’s built-in “511” generator and detector are working prop-
erly.

5.3  POWER UP

Once the Model 1140A is properly installed, it should operate

transparently—as if it were a standard cable connection. Since operat-
ing power is derived from the RS-232 data and control signals; there is
no “ON/OFF” switch. All data signals from the RS-232 interface are
passed straight through.

APPENDIX A

PATTON ELECTRONICS MODEL 1140A

SPECIFICATIONS

Transmission Line:

Dual optical cable

Transmission Mode:

Async. or sync., half or full duplex

Interfaces:

EIA RS-232, CCITT V.24

Data Rates:

0 - 57.6Kbps

Distance:

3.5 miles over continuous fiber

RTS/CTS Delay:

Switch-selectable: No delay, 9.0 mS,
79.5 mS

Receiver Sensitivity:

-38 dBm

Coupled Power Output: > -25dBm

Optic Wavelength:

850 nm

LED Indicators:

Carrier Detect and Fiber Optic Output

Connectors:

DB-25 male or female on RS-232 side; ST 
or SMA connectors on fiber side

Power Supply:

No external power required; uses power 
from RS-232 data and control signals

Temperature Range:

0-60°C (32-140°F)

Altitude:

0-15,000 feet

Humidity:

Up to 95% non-condensing

Weight:

2 oz.

Dimensions:

23.42” x 2.10” x 0.73”

Summary of Contents for 1140A

Page 1: ...MODEL 1140A Miniature Fiber Optic Modem w V 54 Diagnostics SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1140A A Doc 018061UA Revised 10 04 99 An ISO 9001 Certif...

Page 2: ...ll returns must have a Return Materials Authorization number on the outside of the shipping contain er This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages re...

Page 3: ...s extended signaling rates async or sync mode The drawings text and tables on the following pages describe all switch locations positions and functions The Model 1140A has two sets of eight switches y...

Page 4: ...hronous operating mode S1 7 Setting On Asynchronous Off Synchronous S1 8 Carrier Control Method The setting for switch S1 8 determines whether the carrier is con stantly on or controlled by RTS This s...

Page 5: ...6 to the ON position then back to the OFF position S2 8 Setting Off V 54 Enable On V 54 Disable 4 0 INSTALLATION The Model 1140A is easy to install After configuring the DIP switches simply connect th...

Page 6: ...nt is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit C Perform a BER bit error rate test on each unit If the BER test equipment indicates n...

Page 7: ...in place and that the Model 1140A s built in 511 generator and detector are working prop erly 5 3 POWER UP Once the Model 1140A is properly installed it should operate transparently as if it were a s...

Page 8: ...eceive Data From Model 1140A 4 RTS Request to Send To Model 1140A 5 CTS Clear to Send From Model 1140A 6 DSR Data Set Ready From Model 1140A 7 SG Signal Ground 8 DCD Data Carrier Detect From Model 114...

Reviews: