If the system application requires one of more of the  default settings to be changed, it will be
necessary to remove the top cover of the enclosure to access and change the DIP switches or
Jumpers located on the printed circuit board.

Disassembly

Remove the top cover by unscrewing the phillips head screws located on the left and right
sides of the 1205P (CTS ME-V.35).  The configuration switches and Jumpers are located on
the PCB as indicated on the strapping guide in the Appendix of this manual.  After the switch
selection activity is completed, 

re-install the top cover BEFORE connecting to an AC

power source.

Installation

Select an appropriate location accessible to and within six feet of an AC power outlet.  The
outlet must have a ground pin receptacle for product warranty.  

“Straight Through” shielded

cables, terminated in male V.35 (MR-34) connectors should be used to connect the two
terminals to the 1205P (CTS ME-V.35).  Set the switches and Jumpers to match the required
configuration using the descriptions in this chapter and the strapping guide in the appendix.

Equipment Grounding (JP4)

JP4 provides for grounding interconnection in those systems requiring a connection between
(Frame Ground) and (Signal Ground).  

Connect ONLY if required.

CTS Delay, Port 1 (SW2-1,2)

SW2 position 1 and 2 selects RTS to CTS delay for the terminal connected to PORT 1.  RTS
(pin 4) from PORT 1 is looped back to CTS (pin 5) through the delay circuitry.

SW2-1

SW2-2

DELAY

ON

ON

Const

OFF

ON

0mS

ON

OFF

8mS

OFF

OFF

50mS

Summary of Contents for 1205P

Page 1: ...MODEM ELIMINATOR V 35 1 2 0 5 P CTS ME V 35 INSTALLATION AND OPERATIONS MANUAL Doc 113001UA Part 07M1205P A Copyright 2000 Patton Electronics Co All Rights Reserved An ISO 9001 CertifiedCompany...

Page 2: ...nty period shall be two years from the date of shipment of equipment Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is retur...

Page 3: ...radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a resident...

Page 4: ...ration Switch Settings 2 1 Disassembly 2 2 Installation 2 2 Equipment Grounding JP4 2 2 CTS Delay Port 1 SW2 1 2 2 2 CTS Delay Port 2 SW2 4 5 2 3 DSR Control Port 1 SW1 6 2 3 DSR Control Port 2 SW1 5...

Page 5: ...Port Rates up to 2 048Mbps are provided by the internal baud rate generator The generator will provide clocks for both terminal and insure the data is synchronized with the RX Clock in bothdirections...

Page 6: ...pprovals insure the Modem Eliminator will not interfere with any of the other equipment in your data center The Model 1205P Serieshas been tested and found to comply with the limits for a Class A comp...

Page 7: ...let Factory Configuration Switch Settings The 1205P CTS ME V 35 is configured prior to shipment with the switches set to the followingdefaultpositions Switch 1 2 and 3 to OFF 1 4 5 and 6 to ON Baud Ra...

Page 8: ...n AC power source Installation Select an appropriate location accessible to and within six feet of an AC power outlet The outlet must have a ground pin receptacle for product warranty Straight Through...

Page 9: ...to ON to select DSR on Port 1 switching in response to DTR from Port 2 switching Set SW1 position 5 to OFF to set DSR on Port 2 to be forced ON DCD Control Port 1 SW2 6 SW2 position 6 selects DCD cont...

Page 10: ...ate Selection SW1 1 2 3 4 Selection of internal rates is provided by configuration of SW1 positions 1 through 4 and JP7 through JP10 if the High Speed Option has been installed by the factory The foll...

Page 11: ...be utilized by setting SW1 positions 1 through 4 to ON JP10 Installed JP7 JP8 JP9 Removed 256K JP9 Installed JP7 JP8 JP10 Removed 512K JP8 Installed JP7 JP9 JP10 Removed 1 024M JP7 Installed JP8 JP9 J...

Page 12: ...rce 100 120 200 240VAC 50 to 60Hz 0 16 0 08A switchable Environmental Oper Temp 32 to 122 F 0 to 50 C Rel Humidity 5 to 90 non condensing Altitude 0 to 10 000 feet Dimensions Height 1 75 inches 4 44 c...

Page 13: ...CS CD TC RC JP10 JP9 JP8 JP7 2 048Mbps HS Option 1 024Mbps HS Option 512Kbp s HS Option 256Kbp s HS Option Install Only One Jumper to Select the Required Rate ONLY ON THE OPTIONAL HS VERSION Port 1 1...

Reviews: