background image

The table below shows the factory default jumper settings for the 75

ohm rear card. Following the table is a description of each jumper’s
function and possible settings. When configuring the jumpers, take
care not to lose the individual straps.

LK1: Receive Shield-to-Ground Connection

This setting determines whether or not the RX shield is connected

to earth ground. This connection may help EMC performance in some
cases.

LK1

Setting

Strap On

RX Shield-to-GND Connection Made

Strap Off

RX Shield-to-GND Connection Broken

LK2: DTE Signal Ground-to-Frame Ground (with Resistor)

This setting determines whether or not the DTE signal ground

(DB-15 pin 8) is connected to frame ground (pin 1) by way of a 100
ohm resistor. This connection is recommended as a current limiter for
ground fault events.

LK2

Setting

Strap On

SGND-to-FGND Connection Made

Strap Off

SGND-to-FGND Connection Broken

4.0  INSTALLATION

This section describes the functions of the Model 1000R16 rack

chassis, tells how to install front and rear Model 2703RC cards into the
chassis, and provides diagrams for wiring the interface connections
correctly.

4.1  THE MODEL 1000R16 RACK CHASSIS

The Model 1000R16 Rack Chassis (Figure 6, below) has sixteen

device card slots, plus its own power supply. Measuring only 3.5” high,
the Model 1000R16 is designed to occupy only 2U in a 19” rack.
Sturdy front handles allow the Model 1000R16 to be extracted and
transported conveniently.

4.1.1  THE RACK POWER SUPPLY

The power supply included in the Model 1000R16 rack uses the

same mid-plane architecture as the modem cards. The front card of
the power supply slides in from the front, and the rear card slides in
from the rear. They plug into one another in the middle of the rack.
The front card is then secured by thumb screws and the rear card by
conventional metal screws.

11

12

Figure 6. Model 1000R16 Rack Chassis with power supply 

WARNING!

There are no user-serviceable parts in the

power supply section of the Model 2703RC. Voltage set-
ting changes and fuse replacement should only be per-
formed by qualified service personnel. Contact Patton
Electronics Technical support at (301)975-1007 for more
information.

75 OHM REAR CARD JUMPERS

Jumper

Function

Factory Default

LK1

RX Shield to GND

Strap Off

LK2

(DTE) SGND to FGND

Strap On

Summary of Contents for 2703RC

Page 1: ...l us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 97...

Page 2: ...installation If the Model 2703RC does cause interference to radio or television reception which can be determined by turning the power off or removing the card the user is encouraged to try to correc...

Page 3: ...nal interface to be adapted to X 21 using a special DTE cable available from Patton The Model 2703RC is designed to mount in Patton s 2U high 16 slot rack chassis or 2 4 8 slot Cluster Boxes These hav...

Page 4: ...Switches S1 S8 The configuration switches on S1 S8 may be used to set data inversion the DTE bit rate and clocking modes Default settings of S1 through S8 are shown in the table below Descriptions of...

Page 5: ...d is marked THIS SIDE UP FOR V 35 on one side of the board other side 4 Plug the interface board into the 20 pin header socket with the appropriate interface pointed UP and with the arrow pointing tow...

Page 6: ...ermines whether clocks are common or separate Separate non synchronized clocks are used for the EIA 530 V 35 ter minal interface Common synchronized clocks are used for the X 21 terminal interface If...

Page 7: ...assis and provides diagrams for wiring the interface connections correctly 4 1 THE MODEL 1000R16 RACK CHASSIS The Model 1000R16 Rack Chassis Figure 6 below has sixteen device card slots plus its own p...

Page 8: ...and power card replacement information 4 2 INSTALLING THE MODEL 2703RC INTO THE CHASSIS The Model 2703RC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plu...

Page 9: ...coax cables is isolated from system earth ground 4 4 CONNECTION TO THE TERMINAL DEVICE The Model 2703RC rear cards are wired as Data Circuit Terminating Equipment DCE and are designed to connect dire...

Page 10: ...in evaluating the operation of the local Model 2703RC Any data sent to the local Model 2703RC in this test mode will be echoed returned back to the user device For example char acters typed on the key...

Page 11: ...e 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply Module 1000RPEM V 120 240V CE Compliant Rear Power Entry Module 1000RPSM V 120 240V CE Compliant Front Power Supply Module...

Page 12: ...baluns electronic data switches data line surge protectors multiplex ers transceivers hubs print servers and much more We produce these prod ucts at our Gaithersburg MD USA facility and can custom ma...