3040/V35
139001UA
2-3
I
NSTALLATION
A
ND
O
PERATIONS
M
ANUAL
S
ETUP
& I
NSTALLATION
P
ATTON
E
LECTRONICS
C
O
.
Equipment Grounding (SW15-1)
Switch SW15-1 provides for grounding interconnection in those systems requiring a
connection between (Frame Ground) and (Signal Ground). Connect ONLY if required.
RTS To CTS Delay (SW16-1,2,3)
If a CTS delay is desired, set SW16-1, 2 and 3 to the required value as indicated below.
SW16-1
SW16-2
SW16-3
Time
ON
ON
ON
No Delay
OFF
ON
ON
1mS
ON
OFF
ON
2mS
OFF
OFF
ON
4mS
ON
ON
OFF
8mS
OFF
ON
OFF
16mS
ON
OFF
OFF
32mS
OFF
OFF
OFF
64mS
Anti-Streaming (SW18-1,2,3)
The maximum data block size is user selectable via switch SW18- 1, 2 and 3. As shown
below eight block sizes are provided to the user. To disable anti-streaming set SW18-8 to the
OFF position. The maximum block size is normally defined at the time of installation.
SW18-1
SW18-2
SW18-3 CLOCKS
ON
ON
ON
1024
OFF
ON
ON
2048
ON
OFF
ON
4096
OFF
OFF
ON
16 K
ON
ON
OFF
64 K
OFF
ON
OFF
256 K
ON
OFF
OFF
1 MEG
OFF
OFF
OFF
2 MEG