Cable installation
25
Model 3092 iDSL DACS Getting Started Guide
2 • Hardware installation
Figure 7. DC connector, - DC and + DC Input view
4. Repeat steps 1 through 3 to install the remaining DC power connection.
Grounding the Model 3092 - AC and DC Units
Do the following:
1. Assemble a ground wire using #10 AWG wire with green-colored insulation and two ring terminals. Make
the wire long enough to reach one of the following ground sources:
– The building ground rod (generally located at the site’s main service entrance)
– A sprinkler system pipe
– A cold-water pipe
– Building structural steel
2. Install the ground wire between the grounding stud (see figure 6) and the grounding source.
To avoid the risk of personal injury, the distance between ground and the
equipment rack must not exceed the distance specified in either local electrical
codes or the National Electrical Code.
Summary of Contents for 3092
Page 6: ...Contents Model 3092 iDSL DACS Getting Started Guide 6 ...
Page 12: ...Model 3092 iDSL DACS Getting Started Guide 12 ...
Page 55: ...Introduction 55 Model 3092 iDSL DACS Getting Started Guide 5 Troubleshooting and maintenance ...
Page 66: ...5 Troubleshooting and maintenance Model 3092 iDSL DACS Getting Started Guide 66 Maintenance ...
Page 71: ...71 Appendix A RJ 21X Wiring Color Chart Chapter contents Introduction 70 ...
Page 74: ...A RJ 21X Wiring Color Chart Model 3092 iDSL DACS Getting Started Guide 74 Introduction ...