EnviroNET Quick Start Guide
7
Switch 8: Remote Configuration
To enable or disable Remote Configuration, push toggle switch eight (8) up or down.
Refer to
table 8
for settings.
Note
The S2-8 switch applies to the remote unit only. If enabled, the remote unit will follow the dip switch
configuration of the local unit. If disabled, the remote unit will use its own dip switch setting to deter-
mine its Ethernet operating mode and Ethernet Shutdown mode configuration. The S2-8 switch does not
affect the data rate. The data rate will always follow the local configuration.
4.2 EnviroNET Model 2168
EnviroNET Model 2168 uses DIP switch S1 to configure the line rate, symmetric or asymmetric, Ethernet full auto
negotiation capability or limited auto sense. Table 9 shows a summary of each switch.
Switch 1: Ethernet Auto Sense
To configure the unit for full auto sense capability or limited auto sense capability, push the first toggle switch up
or down. Full Auto sense capability consists of standard Ethernet Auto sensing (100BaseT full duplex, 100BaseT
half duplex, 10BaseT full duplex, and 10BaseT half duplex). Limited Auto sensing capability consists on only
auto sensing for 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex. The limited auto negotia-
tion feature is used when an Ethernet device does not comply with IEEE 802.3x (back pressure flow control) at
100M full duplex
.
Refer to
table 10
for settings.
Table 8.
Remote Configuration
S2-8
Description
ON
Remote Configuration Enabled
OFF
Remote Configuration Disabled
Table 9.
S1 Summary
Position
Description
S2-1
Ethernet Auto Sense
S2-2
Line Rate
S2-3
Line Rate
S2-4
Line Rate
S2-5
Reserved
S2-6
Reserved
S2-7
Reserved
S2-8
Reserved
Table 10.
Ethernet Auto Sense Selection Chart
S1-1
Setting
OFF
Full Auto Negotiation (Factory Default)
(100 Mbps, Full or Half Duplex)
(10 Mbps, Full or Half Duplex)