Creating and modifying global configuration templates
121
Model 1001MC Operations Guide
6 • Model 1095RC management
– normal(3)
9.
Configure the
Remote Framing Mode
pop-up menu using the following choices:
– slotted(0)
– normal(3)
10.
When you have finished setting the configuration, click on the
Submit
button to save the changes.
Note
If you receive an
invalid configuration
error after creating a configura-
tion, it is resulting from an illegal combination of variables. Refer to sec-
tion
“Illegal configuration messages”
on page 118 for more
information.
Refer to section
“Applying a template”
on page 125 to activate the template.
Modifying a template
This section describes how to modify a global configuration template. The Patton Model 1095 enables the
Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the
many different applications that are supported, care must be taken when setting the configuration of your
modems. There are several illegal combinations of variables that could cause problems with the modems if
implemented incorrectly. Be sure to read the following information before creating a template:
•
Configuration rules—Things to keep in mind when creating a template (see section
“Configuration rules”
on page 121)
•
Notes on clock mode settings (see section
“Notes on clock mode settings”
on page 122)
•
Notes on framing mode settings (see section
“Notes on framing mode settings”
on page 122)
•
Illegal configuration messages (see section
“Illegal configuration messages”
on page 122)
After reviewing the rules and notes, go to section
“Procedure for modifying a template”
on page 123 to learn
how to modify a template.
Configuration rules
Keep in mind the following when modifying a template:
•
If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit
must
have the Local Clock Mode set to
external
and the Framing Mode set to
slotted
.
•
If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site,
the units
must
have the Clock Mode set to
external-external
and the Framing Mode for both the local and
remote units
must
be set to
slotted
.
•
If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode
must
be set to
normal
.
•
The system administrator should only set the Clock Mode to
external-external(4)
if there is an IM2RC/K
installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site.
•
When setting a unit for the external clock mode, the unit
must
have an external clock source in order to make
a link. When using either an IM2RC/K or an IM1/K, the
K
module will always provide the external clock for