Model 3088RC Configuration page MIB variables description
207
Model 1001MC Operations Guide
9 • Model 3088RC management
Configuration Type (configType)
This displays if the 3088RC is using the DIP switch control or software control for its configuration.
Unit Configuration table
This table shows the configurable MIB variables for the set of units. After changes are made, select the
Submit
Query
button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model
3088RC Configuration page.
The following sections explain the MIB variables that are shown in the Unit Configuration table.
Clock Mode (clockMode3088RC)
This variable defines the clock mode for the NetLink-E1 modems. The following options are available:
•
network-CLK(0)
•
internal-CLK(1)
•
external-CLK(2).
DTE Rate (dteRate3088RC)
This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the
number of activated channels.
TX Clock Invert (tcClockInvert3088RC)
•
enable(0)
•
disable(1)
DSL Link Enable (dslLinkEnable3088RC)
•
enable(0)
•
disable(1)
Line Probe (lineProbe3088RC)
Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions
•
enable(0)
•
disable(1)
Line Coding (lineCoding3088RC)
This variable is used to select the G.703 line coding. The following options are available:
•
code-HDB3(0)—HDB3
•
code-AMI(1)—AMI
Line Build Out (lineBuildOut)
This is used to select the line build out. The following options are available:
•
lbo-75ohm(0)—75 ohm
•
lbo-120ohm(1)—120 ohm