4.2  Getting Started

The HD-ENET module supports insertion into or removal from any available expansion slot on the OS1052 and 
OS1063 chassis while the system is powered on and carrying traffic. The following procedure applies to module 
insertion into a system that is powered ON:

After the module is securely installed to the chassis (using the mounted screws on the front panel), the STAT 
LED of the HD-ENET module becomes a solid amber light for about ten seconds after the system detects the 
module.

After the STAT LED turns off, use the OS-10 Node Manager to set the Administrative Type for the slot where 
the module resides to 8-port Ethernet expansion module.

The STAT LED of the module becomes a solid green light when the Administrative Status of the module is set to 
Enabled and the Operational Status is in service (IS).

At this point, the module is now ready for the provisioning of Ethernet services using the OS-10 Node Man-
ager or NMS.

5.0  Model 9300 STM-1 Module

This section provides a brief overview of the information that you need to install the 2-port STM-1 module. There 
are two types of STM-1 expansion module: 2-port STM-1 optical interface (STM-1o) module and 2-port STM-1 
electrical interface (STM-1e) module. Table 1 provides the product codes that identify each module type. The 
STM-1 modules require software Release 4.0 and above for operation in the OS1052 and OS1063 platforms.

Table 1. 

Product Codes for the STM-1 Modules

Module Type

Code

Description

Optical

9300-STM1-S11-02

2-port STM-1 optical S-1.1 interface

9300-STM1-L11-02

2-port STM-1 optical L-1.1 interface

Electrical

9300-STM1-075-02

2-port STM-1 electrical 75-ohm G.703 interface

To protect your eyes, never look at the transmit LED or laser of the STM-
1 optical interface (STM-1o) module through a magnifying device while it 
is powered on. Never look directly at a fiber port on the module or at the 
ends of fiber cable when they are powered on.

CAUTION

Summary of Contents for OnSite 9100

Page 1: ...100 9130 9200 9300 Expansion Modules Quick Start Guide Part Number 07M9000 QS Rev B Revised February 20 2012 Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW...

Page 2: ...E1 module follow the procedures in Chapter 7 of the OnSite Series Administrator s Reference Guide Figure 1 shows the alignment and insertion of the HD E1 module into one of the available expansion slo...

Page 3: ...es for access to all 21 E1 ports When installing the cables make sure that the cable bundle does not cause strain on the future bus connector by pulling it up or down or sideways You may tie the cable...

Page 4: ...le The STAT LED of the module turns on to a solid green light when the Administra tive Status of the module is enabled and the Operational Status is in service IS At this point the module is now ready...

Page 5: ...10 Node Manager to set the Administrative Type for the slot wherehe module resides The STAT LED of the module becomes a solid green light when the Administrative Status of the module is set tonabled...

Page 6: ...module is now ready for the provisioning of Ethernet services using the OS 10 Node Man ager or NMS 5 0 Model 9300 STM 1 Module This section provides a brief overview of the information that you need t...

Page 7: ...and carrying traffic The following procedure applies to module insertion into a system that is powered ON After the module is securely installed to the chassis using the mounted screws on the front pa...

Page 8: ...0 pm EST 1300 to 2200 UTC GMT Alternate 41 0 31 985 25 55 Switzerland Monday Friday 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland Copyright statem...

Reviews: