Mounting the SmartNode 2400
101
SmartNode 1000 and 2000 Series Getting Started Guide
7 • SmartNode 2400 installation
Desktop installation
Do the following to install the SmartNode 2400:
1. Remove one of the rubber pads from the adhesive strip (included in the SmartNode installation kit pack)
and place it on a corner on the bottom of the SmartNode 2400 (see
figure 67
).
Figure 67. Pad locations
2. Repeat step 1 to install pads on the remaining three corners on the bottom of the SmartNode 2400.
3. Place the unit on a desktop, shelf or other flat, hard, and secure surface.
Note
Allow sufficient space at the rear of the chassis for cable connections. In
addition you should consider the need to access the chassis for future
upgrades, maintenance and troubleshooting. Multiple SmartNodes can be
stacked one atop the other.
Rack-mounted installation
For rack-mounting, screw holes are provided at standard mounting positions for industry-standard 19-inch
equipment racks.
Note
The SmartNode 2400 requires AC power 100–240V, 50–60 Hz. It
should be installed in an open rack wherever possible. If cabinet
installation is unavoidable then ensure that the cabinet has
adequate ventilation.
Install the rack-mount brackets before you install the SmartNode 2400 in the rack. When installing multiple
SmartNode 2400s in one rack, Patton recommends that you leave one height unit (2.54 cm/1 inch) of clear
space between two devices. Two rack mounting brackets and eight screws for attaching the brackets to the chas-
sis are provided. The screws for installing the chassis in a rack are not included.
Model
Serial No.
Part No.
Eth0 Mac
Eth1 Mac
SN24000 0001-0001
100000020153
40-0003
00.30.2E.00.06.94
00.30.2E.00.08.96
Pad (4 places)