Interface cards descriptions
33
SmartNode 1000 and 2000 Series Getting Started Guide
1 • General Information
In addition, two other elements—the Reset button and power input socket—are available on the rear panel of a
SmartNode 2400 as described in
table 9
.
Figure 14. SmartNode PMC interface cards
Interface cards descriptions
The following interface cards (see
figure 14
) are available for use with the SmartNode 2000 Series devices:
•
IC-4FXS
—Gateway interface card for 4 analog FXS ports (see section
“IC-4FXS Gateway interface card for
4 analog FXS ports”
on page 34)
•
IC-4BRV-8V
—8-channel gateway interface card for ISDN BRI (see section
“IC-4BRV-8V 8-channel gate-
way interface card for ISDN BRI”
on page 35)
•
IC-4BRV
—8-channel gateway interface card for ISDN BRI (see section
“IC-4BRV 8-channel gateway
interface card for ISDN BRI”
on page 38)
•
IC-E1V
—30-channel E1 gateway interface card for ISDN PRI (see section
“IC-E1V 30-channel E1 gate-
way interface card for ISDN PRI”
on page 45)
Table 9. SmartNode 2400 Reset button and power line socket on rear panel
Element
Description
Reset button
The button has three different functions:
•
Manual Restart—
During normal operation pressing and releasing the reset button
will cause a system reboot. The application will be restarted without any change to the
existing SmartWare configuration.
•
Restoration—
Pressing and holding the reset button for 5 seconds will restore the fac-
tory configuration and automatically reboot the system.
Note
In this case the existing IP SmartWare configuration is lost.
•
Boot loader—
Powering the SmartNode while pressing the reset button for 5 seconds
will cause the factory-fitted boot loader to start in place of the application. The boot
loader uses a minimal set of parameters. In case the application does not start correctly,
the boot loader can be used as a fallback to download a new software version.
100–240 VAC
50–60 Hz
Electricity supply socket for mains power cable.
The mains supply
must be secured with an external fuse or circuit-breaker,
with a maximum tripping current of 16A.
WARNING