SmartNode 4650 overview
17
SmartNode 4650 Getting Started Guide
1 • General information
Table 2. Rear panel ports
Port
Description
WAN ETH 0/0
Auto-MDX Fast-Ethernet port, RJ-45 (see
figure 2
), connects the unit to an Ethernet
WAN device (for example, a cable modem, DSL modem, or fiber modem).
LAN ETH 0/1
Auto-MDX Fast-Ethernet port, RJ-45 (see
figure 2
), connect the unit to an Ethernet
LAN (for example, a PC, printer, or wireless bridge).
BRI 0/0
ISDN BRI TE/NT port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The inter-
face may be used as fallback if connected to an NT. The port can be switched
between TE and NT mode.The interface is internally terminated with 100 Ohm.
Point-to-point or point-to-multipoint configurable. If the port is in NT mode a phantom
power supply can be switched on to supply connected phones with power.
BRI 0/1
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The inter-
face may be used as fallback if connected to an NT. The port can be switched
between TE and NT mode.The interface is internally terminated with 100 Ohm.
Point-to-point or point-to-multipoint configurable. If the port is in NT mode a phantom
power supply can be switched on to supply connected phones with power.
BRI 0/2
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
BRI 0/3
(SN4658 only)
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
BRI 0/4
(SN4658 only)
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
Console
Used for service and maintenance, the Console port (see
figure 2
), an RS-232 RJ-45
connector, connects the product to a serial terminal such as a PC or ASCII terminal
(also called a dumb terminal). (9600 bps, 8 bits, no parity, 1 stop bit, no flow con-
trol).
100-240 VAC 50-
60 Hz
Electricity supply socket for mains power cable. (see
figure 2
).
Sync Serial port
(option)
Female DB-25 or DB-15 socket provides a V.35 or X.21 serial interface for leased-
line connection to a WAN at rates up to 2 Mbps.