background image

13

Model 3088A Series User Manual 

General observations

Clean the case with a soft slightly moist anti-static cloth

Place the unit on a flat surface and ensure free air circulation

Avoid exposing the unit to direct sunlight and other heat sources

Protect the unit from moisture, vapors, and corrosive liquids

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

General conventions

The procedures described in this manual use the following text conventions:

Electrostatic Discharge (ESD) can damage equipment and impair 
electrical circuitry. It occurs when electronic printed circuit cards 
are improperly handled and can result in complete or intermittent 
failures. Do the following to prevent ESD:

Always follow ESD prevention procedures when removing and 
replacing cards.

Wear an ESD-preventive wrist strap, ensuring that it makes 
good skin contact. Connect the clip to an unpainted surface of 
the chassis frame to safely channel unwanted ESD voltages to 
ground.

To properly guard against ESD damage and shocks, the wrist 
strap and cord must operate effectively. If no wrist strap is 
available, ground yourself by touching the metal part of the 
chassis.

Table 1. General conventions

Convention

Meaning

Garamond blue type

Indicates a cross-reference hyperlink that points to a figure, graphic, table, or sec-
tion heading. Clicking on the hyperlink jumps you to the reference. When you 
have finished reviewing the reference, click on the 

Go to Previous View

 

button

 in the Adobe® Acrobat® Reader toolbar to return to your starting point.

Futura bold type

Commands and keywords are in 

boldface

 font.

Futura bold-italic type

Parts of commands, which are related to elements already named by the user, are 
in 

boldface italic

 font.

Italicized Futura type

Variables for which you supply values are in 

italic

 font

Futura type

Indicates the names of fields or windows.

Garamond bold type

Indicates the names of command buttons that execute an action.

CAUTION

Summary of Contents for 3088A Series

Page 1: ...007 E mail support patton com WWW www patton com Part Number 07M3088A Rev A Revised March 30 2012 Important This is a Class A device and is intended for use in a light industrial environment It is not...

Page 2: ...oduct should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modificati...

Page 3: ...4 Operation 41 5 Remote console operation 45 6 Software Upgrade 49 7 Reset configuration to factory defaults 51 8 Contacting Patton for assistance 53 A Compliance information 56 B Specifications 58 C...

Page 4: ...input connector 16 External AC universal power supply 16 External 48 VDC power supply 17 2 Configuration 18 Introduction 19 Software CLI configuration 19 Hardware DIP switch configuration 19 Configur...

Page 5: ...network 38 Connecting power 39 External AC universal power supply 39 DC Power 40 4 Operation 41 Introduction 42 Power up 42 LED status monitors 42 Power Green 42 DSL Green 42 Link Green Model K 42 Te...

Page 6: ...C Part 15 57 CE Declaration of Conformity 57 Authorized European Representative 57 B Specifications 58 Clocking modes 59 DTE rate 59 Serial interface 59 Serial connector 59 Diagnostics 59 Status LEDs...

Page 7: ...lues for software configurable parameters 64 D Factory replacement parts and accessories 66 Factory replacement parts and accessories 67 E Interface pinouts 68 Line port 69 RS 232 interface 69 V 35 in...

Page 8: ...Model 3088A D to X 21 DTE or DCE 36 8 120 Ohm RJ 48C E1 interface 37 9 RJ 45 cable diagram for E1 connection 37 10 Model 3088A K rear panel 38 11 DC Power Supply 40 12 Model 3088A front panel 42 13 Mo...

Page 9: ...l 3088A Series S1 DIP Switch Functions Configuration 23 4 Model 3088A Series S3 DIP Switch Functions Test Modes and Patterns 23 5 S4 2 through S4 8 Data Rate DIP switch settings 24 6 3088A Clocking 26...

Page 10: ...page 45 describes how to install and operate the OnSite CPE Chapter 6 on page 49 describes how to configure the OnSite CPE save the configuration reset the CPE to the factory default condition and upg...

Page 11: ...lights The shock hazard symbol and WARNING heading indicate a potential electric shock hazard Strictly follow the warning instructions to avoid injury caused by electric shock The alert symbol and WAR...

Page 12: ...s are rated for proper voltage current anticipated temperature flammability and mechanical serviceability WAN LAN PSTN ports connections may have hazardous voltages present regardless of whether the d...

Page 13: ...s good skin contact Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground To properly guard against ESD damage and shocks the wrist strap and...

Page 14: ...hapter 1 General information Chapter contents OnSite 3088A overview 15 Serial interface types 15 Features 15 Power input connector 16 External AC universal power supply 16 External 48 VDC power supply...

Page 15: ...ell as in band management Figure 1 OnSite 3088A Serial interface types The Model 3088A versions listed below provide the following types of built in serial interfaces Model 3088A A provides an RS 232...

Page 16: ...is a 2 5 mm barrel receptacle with the center conductor positive see figure 2 Rated voltage 5 VDC Rated current 1 A Figure 2 Power connection barrel receptacle 5 VDC diagram External AC universal powe...

Page 17: ...mm pitch Transient over voltage protection 100VDC at 2 ms Output Rated voltage 5 VDC 5 5W Rated current 1 A DC 6 inch cable terminated with 2 5 mm barrel plug center positive The external DC adaptor...

Page 18: ...s 22 DIP switch settings 23 S4 2 through S4 8 Data Rate 24 DCE DTE operation 26 Ethernet Management Port 27 Help Commands 29 System Configuration Commands 29 System Status Commands 30 DSL Configuratio...

Page 19: ...tion you must first set the DIP switches to a position other than all OFF or all ON before powering up the OnSite When all the DIP switches are set to any position other than all OFF or all ON the OnS...

Page 20: ...ts Defines the total number of serial E1 timeslots utilized This value must be less than or equal to DSL timeslots 3 89 RS 232 3 89 V 35 3 89 X 21 1 32 E1 Timeslot Mapping Model K Defines E1 to DSL ti...

Page 21: ...nSite passes alarms detected on one E1 net work over the DSL link to the remote E1 network Enabled or Disabled Clock Mode Defines the clock source operation for both DSL and serial E1 ports as follows...

Page 22: ...the S1 1 DIP switch to the ON position and power cycle the unit For information on how to upgrade the software refer to Chapter 6 Software Upgrade on page 49 For more information on applying factory...

Page 23: ...less than 32 a data rate set at 1984 or less on DIP switch S4 For the Unframed setting timeslots must be set to a value equal to 32 the 2048 data rate on DIP switch S4 S1 3 ON CRC OFF Fractional Unfr...

Page 24: ...ON ON OFF 512 OFF OFF OFF OFF ON ON ON 576 OFF OFF OFF ON OFF OFF OFF 640 OFF OFF OFF ON OFF OFF ON 704 OFF OFF OFF ON OFF ON OFF 768 OFF OFF OFF ON OFF ON ON 832 OFF OFF OFF ON ON OFF OFF 896 OFF OFF...

Page 25: ...FF OFF OFF ON 3264 OFF ON ON OFF OFF ON OFF 3328 OFF ON ON OFF OFF ON ON 3392 OFF ON ON OFF ON OFF OFF 3456 OFF ON ON OFF ON OFF ON 3520 OFF ON ON OFF ON ON OFF 3584 OFF ON ON OFF ON ON ON 3648 OFF ON...

Page 26: ...36 ON OFF OFF ON OFF OFF ON 4800 ON OFF OFF ON OFF ON OFF 4864 ON OFF OFF ON OFF ON ON 4928 ON OFF OFF ON ON OFF OFF 4992 ON OFF OFF ON ON OFF ON 5056 ON OFF OFF ON ON ON OFF 5120 ON OFF OFF ON ON ON...

Page 27: ...serial interface provides the clock for the DSL interface RS 232 V 35 X 21 X 21 can only be set to DCE if DTE signal element timing is provided to pins 7 14 Otherwise it must be set to DTE Receive Re...

Page 28: ...ther we are transi tioning from out of sync to in sync acquiring sync or vice versa losing sync Typically when the link is training the sync state goes from out of sync to acquiring sync to in sync DS...

Page 29: ...nsole recognizes System Configuration Commands The following commands allow the user to configure the system system set password password Sets the system password 1 10 characters system set devicetype...

Page 30: ...error counters line condition noise margin and test mode status DSL Clear Errcntrs Command The dsl clear errcntrs command clears the error counters E1 Configuration Commands e1 set linetype e1 unframe...

Page 31: ...mand Line Interface Session 3088A K Command Shell Password 3088A system show config clocking clock mode receive recover dsl timeslots 31 system circuit id Patton Model 3088A interface timeslot map fff...

Page 32: ...system set circuitid 3088A K Circuit ID 3088A system save config 3088A system show config clocking clock mode receive recover dsl timeslots 31 system circuit id 3088A K Circuit ID interface timeslot...

Page 33: ...unit via the ForeFront Model 3096RC at the Central Office CO The stand alone unit at the Customer Premise CP site will automatically configure itself to the DTE rate Bandwidth Allocation defined at th...

Page 34: ...ial interface 36 Connecting the Model 3088A to a DCE or DTE device 36 Connecting the Model 3088A K serial interface 37 Connecting the Model 3088A K to an E1 Network 37 Connect twisted pair 120 ohm to...

Page 35: ...properly the Model 3088A needs one twisted pair of metallic wire This twisted pair must be unconditioned dry metallic wire between 19 0 9mm and 26 AWG 0 4mm the higher number gauges will limit distanc...

Page 36: ...uration is DCE for connection to DTE data terminal equipment such as a router However the serial interface on the 3088 A may be configured as DTE data terminal equip ment for connection to DCE such as...

Page 37: ...e table following it to make the proper connections The connector pinout and signals are shown in figure 8 Figure 8 120 Ohm RJ 48C E1 interface Use the following connection diagram to connect the 120...

Page 38: ...network terminates via dual coaxial cable use figure 10 to make the proper connections Figure 10 Model 3088A K rear panel The interconnecting cables shall be acceptable for external use and shall be...

Page 39: ...wer connector on the Model 3088A Note The Model 3088A powers up as soon as it is plugged into an AC outlet there is no power switch The external AC adaptor shall be a listed limited power source that...

Page 40: ...3088A See Figure 11 Figure 11 DC Power Supply There are no user servicable parts in the power supply section of the Model 3088A Fuse replacement should only be performed by qualified service personnel...

Page 41: ...ontents Introduction 42 Power up 42 LED status monitors 42 Power Green 42 DSL Green 42 Link Green Model K 42 Terminal Green 43 TM ER Yellow 43 LOS Red Model K 43 Link Green 43 Activity Green 43 Test m...

Page 42: ...it Figure 12 shows the location of the front panel LEDs Following figure 12 is a description of each LED s function Figure 12 Model 3088A front panel Power Green The Power LED glows solid during norma...

Page 43: ...de Link Green The Link LED shows that there is an active physical connection to the Console Activity Green The Activity LED shows that there is data being transferred through the Console connection Du...

Page 44: ...tow the DSL line Patterns The 3088A can generate and detect 511 patterns These can be initiated either by the middle DIP switch or by the console command dsl set pattern off 511 When the pattern is s...

Page 45: ...apter 5 Remote console operation Chapter contents Introduction 46 Establishing a Remote Console Session 46 How to Connect 46 How to Disconnect 47 Differences in Local and Remote Control Session Behavi...

Page 46: ...shown as success if the DSL link is established 4 At the command prompt enter the command remote console 5 Wait for the message Console Remote console connection established If a DSL link is not estab...

Page 47: ...session How to Disconnect The remote console session ends under any of the following conditions The user enters the command logout A timeout period of 5 minutes elapses since the user has entered a co...

Page 48: ...it is able to do so whether or not the PC far end is in an active local session because the RCS has pri ority over a local console session If the PC near end establishes an RCS while the PC far end i...

Page 49: ...49 Chapter 6 Software Upgrade Chapter contents Introduction 50...

Page 50: ...nnect to the Model 3088A via the Ethernet management port and a Telnet session 2 Enter the system show info command to view the unit s MAC address 3 Configure a BOOTP TFTP server and enter the system...

Page 51: ...51 Chapter 7 Reset configuration to factory defaults Chapter contents Introduction 52...

Page 52: ...e configuration can be reset to factory defaults using DIP switch S1 A factory reset allows a user to recover from a forgotten password To reset to the configuration 1 Turn the Model 3088A off 2 Turn...

Page 53: ...n support headquarters in the USA 54 Alternate Patton support for Europe Middle East and Africa EMEA 54 Warranty Service and Returned Merchandise Authorizations RMAs 54 Warranty coverage 54 Out of war...

Page 54: ...1 253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Online support available at www patton inalp com E mail support e mail sent to support patton inalp com will be answered...

Page 55: ...l be issued upon receipt and inspection of the equipment 30 to 60 days We will add a 20 restocking charge crediting your account with 80 of the purchase price Over 60 days Products will be accepted fo...

Page 56: ...56 Appendix A Compliance information Chapter contents Compliance 57 EMC 57 Safety 57 Radio and TV Interference FCC Part 15 57 CE Declaration of Conformity 57 Authorized European Representative 57...

Page 57: ...the device does cause interference to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the fo...

Page 58: ...en E1 only 59 Terminal Green 60 TM ER Yellow 60 LOS Red Model K 60 Link Green 60 Activity Green 60 Configuration 60 Power and power supply specifications 60 External AC universal power supply 61 Exter...

Page 59: ...48C Model 3088A K strap selectable Diagnostics V 52 compliant 511 pattern generator and detector with error injection mode controlled by front panel switch Local and Remote Loopback control either by...

Page 60: ...ther framing errors or clock slips Clock slips are often caused by a mis configured clock mode Link Green The Link LED shows that there is an active physical connection to the Console Activity Green T...

Page 61: ...sion line Single Twisted Pair Line coding TC PAM Trellis Coded Pulse Amplitude Modulation The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall...

Page 62: ...olation G SHDSL physical connection RJ 45 2 wire polarity insensitive pins 4 and 5 Environment Operating temp 32 122 F 0 50 C Humidity 5 95 non condensing Altitude 0 15 000 feet 0 4 600 meters Third p...

Page 63: ...63 Appendix C Factory default values Chapter contents Factory default values for software configurable parameters 64...

Page 64: ...e is set for 300 seconds 5 minutes Table 7 3088A CA and 3088A D Parameter Default value Clock Mode Receive Recover DSL Timeslots 89 Tx Clock Normal Circuit ID Patton Model 3088A Password superuser Ann...

Page 65: ...K Parameter Default value Clock Mode Receive Recover DSL Timeslots 31 E1 Timeslots 31 E1 Timeslot Map 1 31 E1 Line Type E1 Fractional E1 Line Code HDB3 E1 Line Build Out 75 Ohm E1 Rx Equalizer Disable...

Page 66: ...66 Appendix D Factory replacement parts and accessories Chapter contents Factory replacement parts and accessories 67...

Page 67: ...placement parts and accessories Factory replacement parts and accessories Power Supplies PS 03671H1 00 100 240VAC 12V DC 2A Wall mount power adapter Power Adapters 12 130 European replacement plug 12...

Page 68: ...68 Appendix E Interface pinouts Chapter contents Line port 69 RS 232 interface 69 V 35 interface 70 E1 interface 70 X 21 interface 71 Ethernet Console port 71...

Page 69: ...ource Pin Signal Designation Source 1 Shield Common 14 Secondary TD DTE 2 TD DTE 15 Transmit Clock DCE 3 RD DCE 16 Secondary RD DCE 4 RTS DTE 17 Receiver Clock DCE 5 CTS DCE 18 Local Loopback DTE 6 DS...

Page 70: ...D a DTE Source 14 TxD b DTE Source 3 RxD a DCE Source 15 TxC a DCE Source 4 RTS DTE Source 16 RxD b DCE Source 5 CTS DCE Source 17 RxC a DCE Source 6 DSR DCE Source 18 LL DTE Source 7 Signal Ground 20...

Page 71: ...eive Data A DCE Source 5 I Indication A DCE Source 6 S Signal Element Timing A DCE Source 7 BT Byte Timing A DCE Source X DTE Signal Element Timing A DTE source 8 SGND Signal Ground 9 T Transmit Data...

Reviews: