background image

FPX6000 Quick Start Guide

11

Figure 10. 

Transmitter rear panel ports

Go to section 8.2 

“Installing cables on the FPX6000R Receiver”

.

8.2  Installing cables on the FPX6000R Receiver

Do the following:

1. Install cables on the front panel of the FPX6000R (see 

figure 9

 on page 10) as fol-

lows:

– If you are connecting a USB keyboard and mouse, connect the keyboard to 

USB 1

 

and the mouse to 

USB 2

.

2. Open the Windows Device Manager on the PC host and verify that you see the fol-

lowing device: “Mouse, keyboard & pen: Dante AV PDS keyboard/mouse”.

3. Install cables on the rear panel of the FPX6000R Receiver (see 

figure 11

 on page 

12) as follows:

– Connect the HDMI 2.0/1.4b video endpoint (a high-quality 4K monitor is recom-

mended) to the 

HDMI Output

 port.

– If you are daisy-chaining multiple devices, connect the Ethernet cable to the 

ETH2

 

port.

ETH2 will not provide PoE power to a daisy-chained device. 

The USB ports can only be used by HID-class devices such as a keyboard and 
mouse. USB flash drives and hard drives are not supported.

If a 1080p monitor is used instead of a 4K monitor, the FPX6000R will automat-
ically scale the 4K output to 1080p.

ETH2 will not provide PoE power to a daisy-chained device.

Summary of Contents for FiberPlex FPX6000 Series

Page 1: ...ght industrial commercial or residential environment It is not intended for use in a heavy industrial environment REGULATORY MODEL NUMBER FPX6000D4 Part Number 50000141 Rev A Revised November 18 2021...

Page 2: ...the device indicates direct current DC In accordance with the requirements of council directive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you separate...

Page 3: ...24 48 VDC PS 03671H1 021 Power Supply AC DC Universal Input 54 VDC 1 2 A 65 W FP101E SFP BT90 52 Industrial Gigabit SFP Media Converter with IEEE802 3bt Power Injector 90 W 10 100 10000Base TX RJ45 1...

Page 4: ...0 Connecting Power on page 12 4 Install the Dante Controller software Refer to section 10 0 Installing the Dante Controller Software on page 13 to download and install the software 5 Configure the FP...

Page 5: ...FPX6000 Quick Start Guide 5 Figure 1 VESA mounting bracket holes Figure 2 VESA mounting holes example 1 Locate the VESA mounting holes on the rear panel of the TV or monitor see figure 2...

Page 6: ...al that came with the TV or monitor 3 Place the FPX6000 in the bracket see figure 3 Figure 3 Placing the device on the VESA mounting bracket 4 Use 4 mounting screws included with the bracket to secure...

Page 7: ...es in a 19 inch rack using the rack mounting bracket see figure 5 Figure 5 Rack mounting bracket 1 Remove 4 screws from below the rear panel as shown in figure 6 Figure 6 Removing the 4 screws from th...

Page 8: ...rews that were removed in step 1 see figure 8 Figure 8 Installing 4 screws to the underside of the rack mount 4 If there is another FPX6000 to install in the bracket go to step 5 Otherwise use 4 mount...

Page 9: ...ing mounting hardware appropriate for the wall material 3 Place the FPX6000 in the bracket as shown in figure 3 on page 6 4 Use 4 mounting screws included with the bracket to secure the FPX6000 in the...

Page 10: ...rear panel of the FPX6000T Transmitter see figure 10 on page 11 as follows Connect an HDMI 2 0 1 4b video source input for example a PTZ camera broadcast camera or video player outputting up to 4Kp60...

Page 11: ...ard pen Dante AV PDS keyboard mouse 3 Install cables on the rear panel of the FPX6000R Receiver see figure 11 on page 12 as follows Connect the HDMI 2 0 1 4b video endpoint a high quality 4K monitor i...

Page 12: ...ise connect the power supply cable to the 48 VDC at 30 W port see figure 10 on page 11 for the Transmit ter or figure 11 on page 12 for the Receiver then go to step 3 2 Connect the Dante Network Ether...

Page 13: ...n All OK Amber Booting up awaiting sync Red System failed to boot correctly Off No power Sync Solid Green Dante network clock slave sync achieved Blinking Green Dante Network clock master Amber Syncin...

Page 14: ...ontroller on Windows OS To install Dante Controller you will need to be logged on with administrator privileges Do the following to install the Dante Controller 1 Log on to your computer as an adminis...

Page 15: ...nse text and if you accept the terms of the agreement click Agree 6 If you do not accept these terms click Disagree to terminate the installation 7 Dante Controller software has been installed Refer t...

Page 16: ...y see a gray hourglass symbol usually very briefly to indicate that the subscription is in process If there is a problem with the subscription a warning or an error symbol may appear If many devices h...

Page 17: ...in red squares Figure 14 Displaying FPX6000T signal sending capabilities 5 Locate the FPX6000R in the receive channel on the left hand side of the Dante Con troller then click the sign next to the Un...

Page 18: ...ical services If you have technical questions about the FPX6000 begin your search for answers by using our Knowledge base at https www patton com support kb asp To subscribe to multiple channels at th...

Page 19: ...to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the fol lowing measures moving the compu...

Page 20: ...any in the United States and other countries FiberPlex is a trademark licensed to Patton Electronics Company The Adopted Trademarks HDMI HDMI High Definition Multimedia Interface and the HDMI Logo are...