Identification of the SmartNode Devices via SNMP
45
SmartNode 5480 & 5490 User Manual
B
•
Specifications
Identification of the SmartNode Devices via SNMP
All SmartNode devices have assigned sysObjectID (.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID)
numbers (see
Table 11
).
According to
Table 11
, an SNMP get request to
.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID
of a Smart-
Node 5480/32P/EUI device reads out a numeric OID of
1.3.6.1.4.1.1768.100.4.24.1
. The mapping of the
sysObjectID to each of the SmartNode model is realized with the SmartNode product identification MIB.
Table 11. SmartNode Models and their Unique sysObjectID
SmartNode Model
SysObjectID
SN5480/32P
.iso.org.dod.internet.private.enterprises.patton.products.sn4970.1
1.3.6.1.4.1.1768.100.4.24.1
SN5480/64P
.iso.org.dod.internet.private.enterprises.patton.products.sn4970.2
1.3.6.1.4.1.1768.100.4.24.2
SN5490/32P2GS
.iso.org.dod.internet.private.enterprises.patton.products.sn4970.3
1.3.6.1.4.1.1768.100.4.24.3
SN5490/64P2GS
.iso.org.dod.internet.private.enterprises.patton.products.sn4970.4
1.3.6.1.4.1.1768.100.4.24.4
The SNMP agent running in SmartWare is SNMP version 1
(SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP
version 3 (SNMPv3) are not currently supported.
IMPORTANT