Paul  Wegener  GmbH 

 

 

 

 

 

 

 

 

 

         

6

Start-up instruction

Please, consider following references during initial operation of the modem:
•  Initially, install the software PWB-Soft
•  Connect the iModem to power supply
•  Then connect the iModem to PC by means of data cable for online-connection. 
•  Start the

 PWB-Soft.

• 

Adjust the interface in the dialog box „Connect“.

•  Open “iModem” dialog in the menu “Module”
• 

Click on the „Connect“ button.

• 

When the connect dialog appears, adjust in the iModem field to „automatic“.

•  Connect the modem to the PC/laptop.
• 

To open the iModem dialog, click on the modem number in the main dialog.

• 

Click on the button „configuration“.

• 

Carry out all necessary settings. After confirming via „transmit“, the iModem will be configured again.

•  Before you insert the SIM card, enter the correct PIN number to avoid disabling the card.

Hardware iModem

The iModem is delivered in aluminium-form housing with degree of protection IP 65. A fixed online cable 

provides connection to a data logger. Depending on online port type at the data logger, an infrared or R232 

interface is provided. PC connection to data logger and iModem is done via online port of the iModem. A 

correct power supply must be provided for connection to a data logger or to an iModem respectively. For this 

purpose, there are different options provided.

1. Battery:

The modem can be equipped both for bypassing power failure periods and for power supply only. The battery 

BP16.5N5L is provided as standard since version iModem5 was introduced. This type supplies necessary 

operating current for GSM/GPRS connection and has no effect of passivation. 

The iModems as of generation 

5 have built-in SuperCaps. The data logger battery type BP16.5N5  is used in this case too. 
2. External voltage:

Depending on type, the modem can be supplied with external voltage between 12 and 14 volt. Normally, the 

device is operated by a 12 V mains adapter. Combined with a lithium battery, an uninterruptible supply can be 

ensured. A backup battery, however, ist not necessary for operating the modem. Any parameter, necessary 

for operation, is saved in non-volatile memories. Date and time are taken from connected data logger.

3. Accumulator:

Power supply for mobile applications is also possible by accumulator (separate manual).
The reasonable adjustment of time slots allows economical operation of devices and long battery 

life. On 

request, a life estimation will be made by the Paul Wegener GmbH.

Summary of Contents for PWBlogg iModem6

Page 1: ...Operating manual Data aquisition system PWBlogg Device version iModem...

Page 2: ...allenstedt All rights reserved No section of the operating manual may be replicated or processed duplicated or distributed using electronic systems in any way print photocopy microfilm or other method...

Page 3: ...2 4 4 Special notes on antenna use in Ex zone 2 5 5 Start up instruction 6 6 Hardware iModem 6 7 Status indication 8 8 Battery change 10 9 Charging the built in accumulator optional 10 10 Technical da...

Page 4: ...g batteries EXPLOSION HAZARD Do not use damaged batteries Do not short circuit batteries 4 Mounting and connecting the device must only be done if there is no potentially explosive atmosphere This dev...

Page 5: ...data acquisition system PWBlogg If the data logger is supplied by external voltage the power supply unit delivered by manufacturer must exclusively be used This is always connected with the supply vo...

Page 6: ...done via online port of the iModem A correct power supply must be provided for connection to a data logger or to an iModem respectively For this purpose there are different options provided 1 Battery...

Page 7: ...located above at a GSM modem Before connecting GSM modem the SIM card must be inserted into the modem For that purpose on iMo dem3 you must open the cover of modem housing The SIM card slot is locate...

Page 8: ...lashing in 0 25 pulse The processor of the iModem is busy eg searching reading the logger sen ding SMS etc Flashing in 0 5s pulse The iModem has recognized a call or established connection to a receiv...

Page 9: ...is connected which inhibits communication to the modem when using N7 data loggers check whether the event send SMS is specified as alarm event whether power supply is ok whether the SIM card is unloc...

Page 10: ...lator Note Depth discharge leads to permanent damage of the accumulator If the accumulator s residual capacity falls below 20 it should be charged We recommend 100 charge before any use The accumulato...

Page 11: ...e batteries can be disposed at collecting points municipal disposal areas or by manu facturer supplier The Paul Wegener GmbH as seller of batteries and electric appliances fulfills its take back oblig...

Page 12: ...as well as small firms EN 61000 6 2 2011 06 subject standard for interference resistance industrial sector EN 60079 0 2019 09 electrical equipment for explosion hazard areas section 0 general requirem...

Page 13: ...13 Operating manual of data acquisition system PWBlogg...

Page 14: ...Paul Wegener GmbH 14...

Page 15: ...15 Operating manual of data acquisition system PWBlogg...

Page 16: ...mbH 16 Paul Wegener GmbH Marienstra e 24 D 06493 Ballenstedt Tel Fax Internet e mail 49 0 39483 96 300 49 0 39483 96 400 www paul wegener de info paul wegener de PWB FORM 2231 EN22 Most recent amendme...

Reviews: