Available control modules
The FOCUS unit can be operated with the following control modules:
•
Control unit LED control panel with the
PEHA
switch programme design (W x H x D in mm: 80 x 80 x 12)
•
Control unit TFT control panel (W x H x D in mm: 102 x 78 x 14)
•
External boost ventilation key(s) (as many as required, potential-free)
•
External sensors with sensor signal 0–10 V or 4–20 mA
LED control panel
The LED control panel is equipped with 7 symbolised short-stroke keys. Pushing a key or a key combination triggers
the associated control functions. The active operating mode is indicated in each operating field via a green or red
LED. The LED control panel with the
PEHA
switch programme design can be installed on the surface or in the wall. In
case of surface-mounted installation a
PEHA
surface-mounted plug socket is needed.
4.2.1.1 LED control panel control functions
Symbol
Description
Explanation
Key
Supply and extract air
mode
Pushing this key sets the supply and extract air mode.
Key
Extract air mode
Pushing this key sets the extract air mode only. The supply air mode
is switched off.
This key must be permanently deactivated
when operating the ventilation unit with a
fireplace! Simultaneous operation of a ventilation
system and fireplace imposes more stringent safety
requirements with regard to low pressure screening
and a switch-off function is required for the
ventilation unit.
Key
Supply air mode
Pushing this key sets the supply air mode only. The extract air mode
is switched off.
Key
Decreasing the fan speed
Pushing this key decreases the fan speed in increments.
Key
Increase fan speed
Pushing this key increases the fan speed in increments.
Key
Boost ventilation mode
Pushing this key activates the boost ventilation during the supply
and extract air mode on fan speed 7 for 15 minutes. At the end of
the boost ventilation time the previously active operating mode
resumes. You can cancel the boost ventilation mode at any time by
pressing another function key.
Key
Reset filter running time
To ensure cyclic filter inspection, the control has an integrated
operating hours counter. The reset filter running time key allows you
to reset the filter running time.
…
Key combination
activate/deactivate
standby mode
The standby function sets the ventilation unit to an energy saving
mode. Repeated pushing of the
–
key until LED L1 is also turned off
activates the standby mode. This status is indicated by the periodic
flashing of LED L8. Pushing the
+
key ends the standby mode and
sets fan speed 1. LED L1 is lit up.
Filter replacement/reset filter
running time
Boost ventilation mode
Decrease/increase fan speed
from 1 to 7
Supply and extract air mode
Extract air mode
Supply air mode
Fig. 2: Operation and information fields LED control panel
Summary of Contents for FOCUS 200 Base
Page 1: ...Translation of the original instruction manual Heat Recovery Unit FOCUS F 200...
Page 49: ...49 Dimensions Fig 43 Dimensional drawing FOCUS...
Page 50: ...50 FOCUS circuit plan Fig 44 Terminal assignment circuit diagram FOCUS...
Page 51: ...51 Master Controller terminal assignment Fig 45 Master Controller terminal assignment...