15
Resetting the filter running time
After completing the filter replacement, the counter for the filter running time must be reset. To reset the filter running
time, press and hold the boost ventilation mode/reset filter running time key for > 3 s. The LED on the fan symbol
stops blinking rapidly.
Use check list A to document the maintenance work completed.
What should I do in case of a fault?
Contact the installation technician in case of a fault. Note down the type of your FOCUS unit according to the type
label on the side of the unit where the air connections are located.
The mains connection must always be established, unless the FOCUS unit has to be shut down due to a serious
fault, for maintenance work or for some other urgent reason.
As soon as the unit is disconnected from the mains, the apartment will no longer be mechanically
ventilated. This may result in moisture and mould problems in the apartment. Therefore, you should
avoid switching off the FOCUS unit for long periods.
Disposal
The unit must be disposed of in an environmentally-friendly manner. Do not dispose the unit with your domestic
waste.
Packaging materials, consumables and waste equipment must be disposed of at the end of their
useful life in accordance with the applicable regulations in your country
.
5
Chapter for qualified persons
Installation requirements
The following requirements must be assured for the correct installation:
•
Installation in accordance with the general and locally applicable safety and installation regulations, such as the
electric and water utilities etc. and in accordance with the regulations stipulated in this instruction manual
•
Frost-free indoor area
•
Power supply 230 VAC, 50 Hz
•
Sufficient space for connecting the ventilation tubes and for maintenance work
Transport and packaging
Proceed with care when transporting and unpacking the FOCUS unit.
Do not remove the unit packaging until right before installation! Before and during interruptions to
the installation, the ventilation tube connections must be closed with the air connector sealing caps
to prevent construction site dust and moisture from entering.
Checking the scope of delivery
If the delivered product is found to be damaged or incomplete, please contact the supplier immediately. Included in
the scope of delivery are:
•
Ventilation unit FOCUS with power cable,
Check the type label to make sure that the unit is the right one (type, version as per type label)
•
Fastening sheet with two self-adhesive spacers (rubber buffers)
•
Control panel
•
Instruction manual
•
Product labels showing energy efficiency
Summary of Contents for FOCUS 200 Base
Page 1: ...Translation of the original instruction manual Heat Recovery Unit FOCUS 200 Base...
Page 30: ...30 Dimensions Fig 33 Dimensional drawing...
Page 31: ...31 FOCUS 200 Base terminal scheme Fig 34 Terminal assignment terminal plan...
Page 36: ...36 PDE Manual_Focus 200 Base_V1 1 V1122 DE Subject to change...