7
The warranty shall be null and void if:
•
The warranty period has elapsed.
•
The installation has not been carried out in accordance with the applicable regulations.
•
The unit is operated without a filter.
•
Original parts have been replaced by non-original parts.
•
Unauthorised changes or modifications to the unit have been made.
•
The defects are due to improper installation, improper use or neglected maintenance of the system.
Liability
The FOCUS unit is intended for use in the mechanical ventilation of apartments, offices and rooms with a similar
purpose. Every other use other than that described in chapter 2 is considered “improper use” and may result in
personal injury or damage to the balanced ventilation unit for which the manufacturer cannot be held liable.
The liability of the manufacturer becomes null and void in the following cases:
•
Failure to observe the instructions specified in this manual pertaining to safety, operation and maintenance.
•
Modifications to the ventilation unit or the use of components that have not been approved or recommended by
the manufacturer.
•
Incorrect installation, improper use or contamination of the system.
•
Original parts have been replaced by non-original parts.
•
The unit is operated without a filter.
3
Safety
Carefully read all safety instructions prior to commissioning the unit to make sure that you use the unit in a safe and
intended way.
Symbols used
You will find the following symbols in this document:
Symbol
Meaning
Important note!
Caution: Risk of affecting the operation of the ventilation system or damaging the unit!
Caution: Risk of personal injury!
Safety regulations
3.1.2.1 Safety instructions – general
Always observe the safety regulations, warning, comments and instructions stated in
this manual. Non-observance results in hazard of injury and hazard of material
damage to the FOCUS unit.
The installation, commissioning and maintenance (except for filter replacement) must
be carried out by an approved technician unless stated otherwise in the instructions.
Implementation of this work by a non-approved technician can result in personal
damage or reduced performance capacity of the ventilation system.
Do not disconnect the unit from the power supply unless instructions to the contrary
are listed in the manual. This can result in the formation of moisture and mould.
Do not make any changes to the unit or to the specifications listed in this document.
Such changes can cause personal injury or lead to reduced performance of the
ventilation system.
To prevent accidents, a damaged mains cable must be replaced by an original cable
by the manufacturer, a person commissioned to carry out maintenance by the
manufacturer or a similarly qualified person.
After installation, have your system engineer/installer instruct you on the unit and the
control panel. The ventilation unit may only be used in accordance with chapter 2
"Intended Use".
Only operate the unit with a closed housing.
Summary of Contents for FOCUS 200 Base
Page 1: ...Translation of the original instruction manual Heat Recovery Unit FOCUS F 200...
Page 49: ...49 Dimensions Fig 43 Dimensional drawing FOCUS...
Page 50: ...50 FOCUS circuit plan Fig 44 Terminal assignment circuit diagram FOCUS...
Page 51: ...51 Master Controller terminal assignment Fig 45 Master Controller terminal assignment...