Error handling
48
11.6
Error bypass with TFT
Bypass in
menu setup and
menu settings
released?
Error bypass
with TFT
Replace
motor
Release
bypass
Yes
No
Check
position,
remove the left
filter and look with
a lamp on silver metal flap
visible
closed
not visible
open
Check, if bypass opens and closes
Menu
Setup
Bypass
test bypass
open bypass
flap not visible
close bypass
flap visible
O.K.?
Yes
No
Bypass
O.K.
Check 24 V
supply voltage
(slave terminal X1 5(+)/6(-))
only if bypass moves
menu!
O.K.?
Yes
No
Replace
slave board
WARNING!
Do not touch the board
for under 230 V power
supply live components!
Check
temperatures
in menu
settings bypass
temperatures
O.K?
Yes
Change
temperatures
No