Fotoelektrik Pauly – Light barriers
E_52692 Ref. 2019-29
20/24
Fotoelektrik Pauly GmbH, Wahrbrink 6, D-59368 Werne, T: +49 2389/402 27-70, F: +49 2389/402 27-77
http://www.fotoelektrik-pauly.de, eMail: info@fotoelektrik-pauly.de
4.8 Electrical connection
Fig.: 4.8: Connection diagram CPV1038
Table 4.8
Terminal block
Naming
Function
1
L1 / +24V DC
Supply voltage
Version ‘AC’:
L1
Version ‘DC’:
+ 24 V
2
N / 0V
Supply voltage
Version ‘AC’:
N
Version ‘DC’:
0 V
PE
PE
Protective earth conductor
3 & 4
NO
11
Make contact 1 (normally open contact) of system 1,
safety-related
5 & 6
NC
11
||NC
12
Break contact of system 1
7 & 8
NO
12
Make contact 2 (normally open contact) of system 1,
safety-related
9 … 11
NO
v
/COM
v
/NC
v
Pollution warning changeover contact
12 & 13
NO
21
Make contact 1 (normally open contact) of system 2,
safety-related
14 & 15
NC
21
||NC
22
Break contact of system 2
16 & 17
NO
22
Make contact 2 (normally open contact) of system 2,
safety-related