Fotoelektrik Pauly – Light barriers
E_52692 Ref. 2019-29
7/24
Fotoelektrik Pauly GmbH, Wahrbrink 6, D-59368 Werne, T: +49 2389/402 27-70, F: +49 2389/402 27-77
http://www.fotoelektrik-pauly.de, eMail: info@fotoelektrik-pauly.de
3. Definitions
– technical data
CPV1038
CPV1038*01
Certificate no.
HSM 09 079
Safety ratings of complete system
in acc. with EN 62061 respectively
EN ISO 13849-1
Safety Integrity Level (SIL)
SIL 1
in acc. with
EN 62061
Performance Level (PL)
PL c
in acc. with
EN ISO 13849-1
Category
Cat. 2
in acc. with
EN ISO 13849-1
DC [%]:
60
in acc. With
EN ISO 13849-1
Safety ratings of the electronic
device
in acc. with EN ISO 13849-1
PFH
d
[h
-1
]:
6,61 x 10
-7
MTTF
d
[a]:
86
n
op
[n/a]
8760
CCF
95
Mission time T
M
[a]
20
Maximum clearance distance
50 m
25 m
Optical systems
2
Safety-related tolerance of the
systematically distancing
accuracy
Maximum 9%
(in accordance with diagram fig. 4.4.3)
Safety-related tolerance of the
distancing accuracy due to
environmental influences
Additional 8%
(by reason of environmental influences,
e.g. fog, steam, smoke)
Power supply / output or current
consumption
(
: Option)
230VAC ± 10 %
/ 16VA
115VAC ± 10 %
/ 16VA
42…48VAC ± 10 %
/ 16VA
24VDC + 20 % / - 10 %
/ ~ 700mA
Connection
2 x cable glands; terminal strip
Switching outputs
Main contact (to switch off the
crane movement)
for each optical system: 2 x relay NO contacts;
supervised and force guided
Status message
for each optical system: 1 x relay NC contact
Pollution warning
1 x relay change-over contact