6 Mounting and installation [specialist]
2020/06
99640x5xx-mub-en – V01
15
WARNING
Risk to life and limb due to electric shock!
Prior to commencing electrical work on the controller, pull the mains
plug!
Only after completing all installation work, plug the mains plug of the
controller into a socket. This avoids an unintentional start of the motors.
ATTENTION
Damage to property!
The installation site must be dry, stable, frost-proof and protected against ultraviolet radiation
in order to prevent material damage of the installation.
1.
Determine the mounting location of the domestic
hot water module near the buffer tank.
The pipes in the heating circuit must not exceed a
length of 4 m (for DN 32).
2.
A drilling template can be used in order to facilitate
the installation. You will find the drilling template on
the station.
3.
Copy the measures for the mounting holes to the
wall.
4.
Drill the holes and insert adequate wall plugs into
the holes.
5.
Turn the screws into the wall plugs in such a way
that about 40 mm of each screw still stick out.
6.
Remove the station from the packaging.
7.
Remove the insulating front shell.
8.
Hang the domestic hot water module onto the
screws. Tighten the screws, so that the sides of the
insulation are flush to the wall.