1 General Information
4
997655910x-mub-en
–
V07
2016/05
1
General Information
Carefully read these instructions before installation and commissioning.
Save these instructions in the vicinity of the installation for future reference.
1.1
About these instructions
These instructions describe the installation, commissioning, function and operation of the
3-line solar stations SolarBloC midi 2D (DN 20) for installations with 2 roofs.
The chapters called [specialist] are intended for specialists only. For other components of the
solar installation, such as collectors, storage tanks, expansion tanks and controllers, please
observe the instructions of the corresponding manufacturer.
1.2
About this product
The station is a premounted group of fittings checked for tightness and used to circulate the
solar fluid in the solar circuit. It is mounted on wall brackets and fixed with clips. The station
contains important components and safety devices for the operation of the installation:
Three ball valves in the flow line and in the return lines
Three check valves (integrated in the ball valves)
Three thermometers in the flow line and in the return lines
Pressure gauge to display the system pressure
Two flow meters to display the flow rate
Two ball valves to reduce the flow rate
Solar pressure relief valve
Airstop for an easy venting
Flush and fill valves