The following syntax is the response for a Job 3 request. You
may need to press
ENTER
or
FEED/CUT
, depending on your
printer before the job response is returned.
Syntax
{J,"Status1 A,B","Status2
A,B,C,D,E","FMT-1","BCH-2"}
"Status1 A,B"
Status1 A contains the field number, in the
format or batch, where an error was found. If
the error is not in the format or batch, a "0" is
returned.
Status1 B contains an error number, which
represents the actual printer error. The error
numbers can be found in Chapter 8,
"Diagnostics and Errors."
Example
{J,"2,612",}
2
is the field number where an error was found.
612
is the error
number, indicating that data is missing or does not match the
format definition for that field.
Error numbers found in Status1 B, always
have a value equal to or greater than 500.
These are considered very serious errors.
"Status2 A,B,C,D,E"
contains the packet type, field type, field
number, parameter, and error number.
Status2
A- Packet Type
represents the MPCLII packet that the error
occurred on. The packet could be Format (
F
),
Batch (
B
), Check Digit (
A
), Graphic (
G
), or
Font (
W
).
7-10
Status Polling
Summary of Contents for Monarch 9825
Page 62: ...2 42 Configuring the Printer ...
Page 92: ...3 30 Defining Fields ...
Page 138: ...5 26 Creating Graphics ...
Page 166: ...7 16 Status Polling ...
Page 212: ...A 14 Samples ...
Page 216: ...A 18 Samples ...
Page 246: ...A N S I S y m b o l S e t B o l d C h a r a c t e r S e t C 4 Symbol Sets Code Pages ...
Page 249: ...C o d e Pa g e 8 5 0 L a t i n 1 C o d e Pa g e 8 5 2 L a t i n 2 Symbol Sets Code Pages C 7 ...
Page 264: ...C 22 Symbol Sets Code Pages ...
Page 268: ...C h e c k D i g i t Wo r k s h e e t ...
Page 293: ......
Page 294: ......