background image

PAGE 5

Presenting a valid user token to the unit will cause the LED to briefly flash Green and the door will unlock.  

The presentation of a barred or unknown user token is indicted by a Red LED display.

The external handle is only engaged once access has been granted.  The inside handle is always engaged.

Normal Operation - LED Indications

Software configuration

Reader

: Local settings for the reader.

Output

: Configures the lock for timed release or toggle mode.

Alarm

: Enables/Disables the door alarm functions.   

 

  

  (requires contact switch)

Events

: Shows the events for this control unit only.

Access Rights

: Lists users who have access through this door.

Door name

: Name the Door.

Door open time

: Set the door open time.

Unlock the Door during

: Holds the door unlocked during this 

timezone. - Set to  'At No Time'  for normal user operation.

Red flash
Red and Green flash together

A valid user card has been presented and the handle is engaged
An invalid user card has been presented - No access granted

LED indications

Green flash

The unit is configuring - Please wait.

The access control unit connects to the Net2 software running on the PC using Paxton Net2Air proprietary 

wireless technology. A Net2Air bridge enables communication from the Net2 software to the Paxton wireless 

products.

Radio signals do not always behave as you might expect.  For example, a cell phone that displays a full signal on 

one part of the site will lose signal completely only a few feet away. These problems can be addressed by using 

the Net2 site surveyor kit  (690-200-US)

See also:  

X

AN1095 - Net2 nano - How does it work? <

 

http://paxton.info/974

 >

X

               AN1096 - How to plan a Net2 nano installation <

 

http://paxton.info/975

 >

X

               Ins-30096-US  - Net2Air site surveyor <

 

http://paxton.info/1193

 >

Net2Air wireless communication

Radio frequency

The unit is set to channel 11 (2.405 GHz). This product should not be installed within 10 feet of any other radio 

(LAN/Wi-Fi) equipment to reduce the possibility of interference.

Red and Green flash alternately

The unit is not bound to a bridge.

Summary of Contents for Net2 PaxLock

Page 1: ... com Net2Air Site Surveyor 690 200 US This access control unit uses wireless communication It is recommended that a Net2Air site surveyor is used to determine the best position for the bridge and control units This wireless unit requires a Net2Air bridge to communicate with the server PC Paxton 1 2 3 4 5 6 7 8 9 AA AA 1 Front Lock Assembly 2 Rear Lock Assembly 3 Door Handle x 2 4 Mounting screw 1 ...

Page 2: ...of damaging the door face when the drill breaks through Step 3 Contact switch optional If a contact switch is to be fitted an additional hole is required in the edge of the door Drill a hole of the required size to receive the switch assembly This should intersect the 5 8 hole drilled previously to take the wiring harness Feed the door contact wires through the door to exit on the inside Ø 16 37 1...

Page 3: ... into the socket in the rear lock assembly Locate the top of the cover over the housing and push flush to the door Clip in the 4 x AA batteries with reference to the label displayed below the holder assembly Step 8 Fitting the batteries Where a contact swich is fitted connect the wires to the terminal block provided on the pcb Step 7 Wiring contact switch option Mounting screws are provided in thr...

Page 4: ...r and waits for a response from Net2 If more than one bridge replies the unit checks the signal strength and selects the strongest bridge to communicate with The Net2 software confirms that the token number is in the database and registers the PaxLock bridge binding The LED s will go out when the process has finished The software must be in commissioning mode which is the default setting If this h...

Page 5: ... handle is engaged An invalid user card has been presented No access granted LED indications Green flash The unit is configuring Please wait The access control unit connects to the Net2 software running on the PC using Paxton Net2Air proprietary wireless technology A Net2Air bridge enables communication from the Net2 software to the Paxton wireless products Radio signals do not always behave as yo...

Page 6: ... to the Net2 PC which responds with any updates This keeps the PaxLock updated even when there is no activity at the door and maximises battery life Sleep mode As the battery voltage falls the unit will update the Net2 server with its battery condition This voltage level is displayed as a colored battery icon alongside the door in the Doors screen When the batteries approach the end of their life ...

Page 7: ...Dimensions Features External use Min Width Height Max Depth Min Max Access Levels Time Zones Door open time ACU s per Net2Air bridge Recommended Events stored in ACU with no server connection Number of Cards Specifications Yes Net2Air bridge data lines per system Net2Air wireless range to ACU The declaration of conformity is available on request Contact details are provided at http paxton info 596...

Reviews: