Battery replacement

1. Remove the inside handle from the door by removing the securing grub screw.

2. Remove the cover by holding the bottom edge and pulling it towards you. The cover will lift off at the top when

    the bottom edge is clear of the housing.

3. Remove and replace batteries.

4. Refit the cover and handle.

Recovery from a flat battery 

Should the battery pack become discharged, the latch will no longer function. 

This could be in the locked or unlocked state.

Holding a PP3  9V battery up to the contacts on the bottom of the unit will allow 

the circuitry to operate normally. 

A valid user card can then be used to open the door to access the batteries.

+ve

-ve

The PaxLock is a standalone unit and stays asleep while there is no user activity. The Net2 server cannot wake 

up the unit. If the PIR is activated or the front button is pressed, it powers up the reader circuits in readiness 

for a token read.  Should nothing occur within 3 seconds, the unit will go back to sleep.

If a token is read, then the PaxLock moves into full operation. The token number is checked against the stored 

database and access is granted or denied as per a standard Net2 control unit.

The PaxLock now sends this data via its Net2Air bridge connection to the Net2 server software. If any updates 

need to be sent to the unit, including changes to the user data, these are transmitted back.  The unit will then 

go back to sleep waiting for further activity.

After 1 hour of inactivity, the PaxLock will send a heartbeat to the Net2 PC which responds with any updates.  

This keeps the PaxLock updated even when there is no activity at the door and maximises battery life.

Sleep mode

As the battery voltage falls the unit will update the Net2 server with its battery condition.  This voltage level is 

displayed as a colored battery icon alongside the door in the Doors screen. When the batteries approach the 

end of their life an Event is sent to Net2.

Using Net2 Trigger and Actions, an email or text message can be sent to a staff member or engineer to 

schedule a battery change.

Low battery warning

During the 1 hour sleep period, any changes made at the PC will not be received. If an immediate 

update is required, the unit must be woken up by pressing the front button or presenting a user card.

Where a door is held unlocked by software, it will still receive updates every hour. To force an 

immediate update, the unit must by activated by pressing the front button.  A card can then be 

presented to initiate the update request.

Where the lock has a key override, this will always be available to unlock the door and gain entry.

Low Power mode is available as a global setting in the Net2 server configuration utility or on individual Doors 

screens. It is very useful for units that require low activity but have a high rate of passing traffic (e.g. corridor). 

In low power mode the PaxLock must be woken up by pressing the front button. This ensures that incidental 

handle or PIR activity does not cause an unnecessary drain on battery power or communications activity.

If woken, the PaxLock will initiate a transmission if it has been asleep for more than 1 hour.  It will always initiate 

an update every six hours.

Low power mode

Summary of Contents for Net2 PaxLock

Page 1: ... com Net2Air Site Surveyor 690 200 US This access control unit uses wireless communication It is recommended that a Net2Air site surveyor is used to determine the best position for the bridge and control units This wireless unit requires a Net2Air bridge to communicate with the server PC Paxton 1 2 3 4 5 6 7 8 9 AA AA 1 Front Lock Assembly 2 Rear Lock Assembly 3 Door Handle x 2 4 Mounting screw 1 ...

Page 2: ...of damaging the door face when the drill breaks through Step 3 Contact switch optional If a contact switch is to be fitted an additional hole is required in the edge of the door Drill a hole of the required size to receive the switch assembly This should intersect the 5 8 hole drilled previously to take the wiring harness Feed the door contact wires through the door to exit on the inside Ø 16 37 1...

Page 3: ... into the socket in the rear lock assembly Locate the top of the cover over the housing and push flush to the door Clip in the 4 x AA batteries with reference to the label displayed below the holder assembly Step 8 Fitting the batteries Where a contact swich is fitted connect the wires to the terminal block provided on the pcb Step 7 Wiring contact switch option Mounting screws are provided in thr...

Page 4: ...r and waits for a response from Net2 If more than one bridge replies the unit checks the signal strength and selects the strongest bridge to communicate with The Net2 software confirms that the token number is in the database and registers the PaxLock bridge binding The LED s will go out when the process has finished The software must be in commissioning mode which is the default setting If this h...

Page 5: ... handle is engaged An invalid user card has been presented No access granted LED indications Green flash The unit is configuring Please wait The access control unit connects to the Net2 software running on the PC using Paxton Net2Air proprietary wireless technology A Net2Air bridge enables communication from the Net2 software to the Paxton wireless products Radio signals do not always behave as yo...

Page 6: ... to the Net2 PC which responds with any updates This keeps the PaxLock updated even when there is no activity at the door and maximises battery life Sleep mode As the battery voltage falls the unit will update the Net2 server with its battery condition This voltage level is displayed as a colored battery icon alongside the door in the Doors screen When the batteries approach the end of their life ...

Page 7: ...Dimensions Features External use Min Width Height Max Depth Min Max Access Levels Time Zones Door open time ACU s per Net2Air bridge Recommended Events stored in ACU with no server connection Number of Cards Specifications Yes Net2Air bridge data lines per system Net2Air wireless range to ACU The declaration of conformity is available on request Contact details are provided at http paxton info 596...

Reviews: