GUIDE SPECIFICATIONS

General

System Description

Furnish a ______________________ 4--way multipoise gas--fired

condensing furnace for use with natural gas or propane (factory--
authorized conversion kit required for propane).

Quality Assurance

Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z

21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue Star

R

and Blue Flame

R

labels. Unit

efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the

latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy

Guide efficiency label.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available upon request.

Equipment

Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and

dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,

and have infinitely variable speed from 600--1200 RPM operating

only when motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower housing to reduce vibration

transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.

(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted

galvanized steel.
Draft Inducer Motor
Draft inducer motor shall be two--speed PSC design.

Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass corrosion-- resistant

aluminized steel of fold--and--crimp sectional design and applied

operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under

negative pressure.
Controls
Controls shall include a micro--processor--based integrated

electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a

self--test feature that checks all major functions of the furnace, and

a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including separate blower speeds for

low heat, high heat, low cooling, high cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.

Cooling airflow will be selectable between 325 to 400 CFM per
ton of air conditioning. Features will also include temporary

reduced

airflow

in

the

cooling

mode

for

improved

dehumidification when a dehumidification--capable thermostat is
used.

Operating Characteristics

Heating capacity shall be _________________ Btuh input;

______________ Btuh output capacity.
Fuel Gas Efficiency shall be________ AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C. external static pressure.
Dimensions

shall

be:

depth_________in.

(mm);

width

__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and

_________________in. (mm) overall with plenum.

Electrical Requirements

Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size

of HACR--type designated circuit breaker shall be _________
amps.

Special Features

Refer to section of the product data identifying accessories and

descriptions for specific features and available enhancements.

E

2012 Payne Heating & Cooling Systems

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Edition Date: 09/12

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: SS---PG96VAT---02

Replaces: SS--- PG96VAT--- 01

PG96V

A

T

Summary of Contents for PG96VAT

Page 1: ...ice S Silicon Nitride Hot Surface Igniter S 4 way multipoise design for upflow downflow or horizontal installations with unique vent elbow and optional through the cabinet downflow venting capability S Full featured variable speed blower motor two speed inducer motor and two stage gas valve S Self diagnostics S Adjustable blower speed for cooling continuous fan and dehumidification S Aluminized st...

Page 2: ...ormance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for this essential component The condensing heat exchanger a stainless steel fin and tube design is positioned in the furnace to extract additional heat Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural ga...

Page 3: ...x 10 11 x 10 11 x 11 Air Filtration System Field Supplied Filter Used for Certified Watt Data KGAWF 06UFR Electrical Data 30040 42060 48080 60080 60100 66120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 7 5 9 2 9 2 11 7 11 8 11 8 Unit Ampacity Amps 10 3 12 4 12 4 15 5 15 6 15 6 Minimum Wire Size AWG 14 14 14 12 12 12 Maximum Wire Length M...

Page 4: ... 5 95 AFUE 6 96 AFUE 7 97 AFUE 24 800 CFM 30 1000 CFM 36 1200 CFM 42 1400 CFM 48 1600 CFM 54 1800 CFM 60 2000 CFM 66 2200 CFM 0 5 ESP Example of a Model Number A12375 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY OPERAT...

Page 5: ... Kit LP to Nat KGAPN42011SP D D D D D D Gas Orifice Kit 42 Nat Gas LH32DB207 D D D D D D Gas Orifice Kit 43 Nat Gas LH32DB202 D D D D D D Gas Orifice Kit 44 Nat Gas LH32DB200 D D D D D D Gas Orifice Kit 45 Nat Gas LH32DB205 D D D D D D Gas Orifice Kit 46 Nat Gas LH32DB208 D D D D D D Gas Orifice Kit 47 Nat Gas LH32DB078 D D D D D D Gas Orifice Kit 48 Nat Gas LH32DB076 D D D D D D Gas Orifice Kit 5...

Page 6: ...20 435 See note 4 OFF ON OFF 780 725 660 615 540 See note 4 OFF ON ON 975 925 875 835 785 750 690 655 610 570 ON OFF OFF 1160 1120 1090 1045 1010 970 920 885 840 800 ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON OFF 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 Clg SW2 Maximum Clg Airflow 2 1705 1650 1595 1545 1475 ...

Page 7: ...ch Settings External Static Pressure ESP SW2 3 SW2 2 SW2 1 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 66120 6 Clg Default OFF OFF OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 Cooling SW2 OFF OFF ON 1015 805 645 550 480 See note 4 OFF ON OFF 1075 975 915 835 765 See note 4 OFF ON ON 1205 1135 1055 1000 935 See note 4 ON OFF OFF 1400 1330 1260 1190 1145 1080 1035 970 905 845 ON OFF ON 1615 155...

Page 8: ...A NA 60 000 23 7 0 119 36 3 210 64 0 235 71 6 NA 80 000 15 4 6 59 18 0 155 47 2 210 64 0 232 70 7 100 000 NA 19 5 8 98 29 9 211 64 3 236 71 9 120 000 NA NA 8 2 4 86 26 2 224 68 3 140 000 4 NA NA NA 79 24 1 158 48 2 4001 to 4500 1219 to 1370 40 000 36 11 0 177 53 9 205 62 5 NA NA 60 000 21 6 4 115 35 1 204 62 2 228 69 5 NA 80 000 14 4 3 56 17 1 150 45 7 202 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 2...

Page 9: ...ent Vent Length TEVL 112 ft Add all of the above lines Maximum Equivalent Vent Length MEVL 127 ft For 2 pipe from Table 1 Is TEVL less than MEVL YES Therefore 2 pipe may be used Example 2 A direct vent 60 000 Btuh furnace installed at 2100 ft 640 M Venting system includes FOR EACH PIPE 100 feet 30 M of vent pipe 95 feet 28 M of combustion air inlet pipe 3 90_ long radius elbows and a polypropylene...

Page 10: ... 8 63 19 2 8001 to 9000 2438 to 2743 40 000 10 3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 140 000 4 NA NA NA 23 7 0 42 12 8 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 ...

Page 11: ... 44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 70 0 71 0 57 0 40 0 20 0 70 0 86 0 71 0 52 0 M 6 1 5 2 4 3 1 8 0 0 6 1 21 3 21 6 17 4 12 2 6 1 21 3 26 2 21 6 15 8 40 40 Ft 15 0 7 0 5 0 0 0 0 0 20 0 61 0 52 0 40 0 24 0 20 0 70 0 64 0 50 0 33 0 M 4 6 ...

Page 12: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended Consult your local building codes COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT APPLICATION FIELD SUPPLIE...

Page 13: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the o...

Page 14: ...IELD 24 V WIRING FIELD 115 208 230 460 V WIRING FACTORY 24 V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire W Y...

Page 15: ...ATION NOTE ALL DIMENSIONS IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters a For 800 CFM 16 in 406 mm round or 14 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in 508 mm round or 14 1 2 x 19 1 2 in ...

Page 16: ...at exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a stainless steel flow through of fin and tube design and applied operating under negative pressure Controls Controls shall include a micro processor based integrated electronic control bo...