Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

info@pcb.com

 

Repair inquiries

rma@pcb.com

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for 8161-011A

Page 1: ...ge Conditioner Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ...ialized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For more information contact your local PCB Piezotronics distributor sales representative or factory customer service representative Returning Equipment If factory repair is required our representatives ...

Page 3: ...ation on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety precautions to avoid personal contact with this voltage This symbol on the unit indicates that the user should refer to the operating instructions located in the manual This symbol indicates safety ea...

Page 4: ...E 住房 O O O O O O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ... O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at least one of t...

Page 6: ... 0 Power Connections 2 3 0 Transducer Cabling 2 4 0 Transducer Excitation 3 5 0 Calibration Resistor 3 6 0 Analog Outputs 3 7 0 Calibration 3 Figures Figure Page 1 Jumper Locations 2 2 SW2 Switch Settings 4 3 Transducer Hookup 6 MANUAL NUMBER 23708 MANUAL REVISION E ECN NUMBER 50103 10 28 19 ...

Page 7: ... to the transducer is made through conventional a shunt technique using an internal calibration resistor A front panel push button provides for calibration in the positive direction 2 0 Power connection The 8161 series is designed to operate on a customer supplied DC power source with a voltage range of 10 to 28 volts Screw terminals 1 and 2 are provided for power connections Reference Figure 3 3 ...

Page 8: ...e to achieve a precisely known equivalent input allowing the instrument sensitivity to be adjusted correctly A 30K ohm resistor is installed at the factory and is used during final checkout of the instrument It should be replaced with the proper value and accuracy for the transducer that it will be used with The resistor is mounted internally on terminals located on the printed circuit board in th...

Page 9: ...time for stabilization of transducer characteristics 4 With the transducer unloaded set the voltage output to ZERO using the coarse and fine zero controls If the current output is to be used set ZERO to 4 mA using the 4 mA adjust 5 Load the transducer to a convenient up scale value which is greater than one half of full scale Adjust the fine span control until the voltage output signal reading is ...

Page 10: ... by the installed calibration resistor 7 If dead weight calibration is not practical and the transducer calibration data is unknown the Equivalent Input value for the factory installed calibration resistor can be approximated as follows if the mV V sensitivity rating of the transducer and the bridge resistance are known X 25000 x Rb K x Rc Where X Equivalent Input of full scale Rb Bridge Resistanc...

Page 11: ...ANUAL 6 1 Ground 2 Vsupply 10 28 VDC 3 Iout 4 20 mA 4 Vout 5 or 10 V 5 Excitation 6 Excitation 7 Signal 8 Signal Figure 3 Transducer Hook up Sig VEXC VSUPPLY 10 28 VDC Ground IOUT VOUT Return VOUT IOUT 4 20 mA VEXC Sig 5 6 7 4 2 8 3 1 ...

Page 12: ...A 2 Physical Size Height x Width x Length 3 35 in x 0 69 in x 2 27 in 89 mm x 18 mm x 58 mm Mounting 35 mm DIN Rail 35 mm DIN Rail All specifications are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right to change specifications without notice ICP is a registered trademark of PCB Group Inc OPTIONAL VERSIONS Optional versions have id...