12
Reference
Nominal
Model
for
measuring
Input/Ouput
Connection
ordering
scope
ratio
Alternating voltage output
C106
P01.1203.04
100 mA... 1000 A
1 mV~ / 1 A~
Sockets
C116
P01.1203.16
10 mA... 1000 A
C107
P01.1203.05
100 mA... 1000 A
1 mV~ / 1 A~
Lead
C117
P01.1203.17
10 mA... 1000 A
1 A... 1000 A
1 mV~ / 1 A~
Lead
C160
P01.1203.08
100 mA... 100 A
10 mV~ / 1 A~
BNC
100 mA... 10 A
100 mV~ / 1 A~
1 A... 1000 A
1 mV~ / 1 A~
C173
P01.1203.09
100 mA... 100 A
10 mV~ / 1 A~
Lead
10 mA... 10 A
100 mV~ / 1 A~
1 mA... 1 A
1000 mV~ / 1 A~
4.3
Precision and dephasing
(in reference conditions)
n
C100 / C102 / C103 / C106 / C107 : 1000 A calibre
Intensity in A~
0,1...10 A
10 A
50 A
200 A
1000...1200 A
Intrinsic error
(1)
≤
3%
(3)
≤
3%
≤
1,5%
≤
0.75%
≤
0.5%
Dephasing
(2)
≤
3°
≤
1.5°
≤
0.75°
≤
0.5°
n
C112 / C113 / C116 / C117 : calibre 1000 A
Intensity in A~
10...100 mA
0,1...1 A
1...10 A
10...100 A
100...1200 A
Intrinsic error
(1)
≤
3%
(4)
≤
2%
(5)
≤
1%
≤
0.5%
≤
0.3%
Dephasing
(2)
(2)
≤
2°
≤
1°
≤
0.7°
n
C122 / C148 : 1000 A calibre
Intensity in A~
1...20 A
20 A
50 A
200 A
1000...1200 A
Intrinsic error
(1)
6%
(6)
≤
5%
≤
3%
≤
1.5%
≤
1%
Dephasing
(2)
≤
5°
≤
3°
≤
1.5°
≤
1°
n
C148 : 500 A calibre
Intensity in A~
1...10 A
10 A
25 A
100 A
500...600 A
Intrinsic error
(1)
6%
(7)
≤
6%
≤
3%
≤
2%
≤
1%
Dephasing
(2)
≤
6°
≤
4°
≤
3°
≤
2.5°
C148 : 250 A calibre
Intensity in A~
1...5 A
5 A
12,5 A
50 A
250...300 A
Intrinsic error
(1)
10%
(8)
≤
10%
≤
5%
≤
2%
≤
2%
Dephasing
(2)
(2)
≤
10°
≤
10°
≤
10°
(1) As % of output signal
(5) + 3
µ
A for C112 / C113 or + 3
µ
V for C116 / C117
(2) Unspecified
(6) + 0.5 mA
(3) + 0.1 mA for C100 / C102 / C103 or + 0.1 mV for C106 / C107
(7) + 1 mA
(4) + 5
µ
A for C112 / C113 or + 5
µ
V for C116 / C117
(8) + 2 mA