5.1 

Turn the scale on/off 

To turn the crane scale on, press and hold the ON/OFF Button on the scale for 3 seconds. 
Now, the display shows the following: 
 

1.  [88888]  

 

2 times 

2.  [   Ert   ] 

 

2 times 

3.  [XXXXX] 

 

capacity of the scale 

4.  [U 6.XX] 

 

current battery voltage 

5.  [-----] 

 

 

waiting for stable 

6.  [    0] 

 

 

reading is stable -> stable indication is active 

 
Now you can measure with the crane scale. 
 
To turn the scale off, press and hold the ON/OFF button on the scale or the OFF button on the remote for 
3 seconds. 

5.2 

Zero function 

If the scale is unloaded but the display does not show “0”, you can zero the scale manually. To do so, just 
press the ZERO button on the remote control. 
 

Note: This cannot be done, if the displayed value exceeds 4 % of the capacity of the scale. If this is the 
case, please contact our customer support. 
 

To display the current zero point, press SHIFT and ZERO on the remote at the same time. 

5.3 

Tare function 

To use the tare function, hang a weight on the scale, wait for the reading to be stable and press the TARE 
button on the remote control or the TARE button on the scale itself. 
The display now shows “0” and the tare indication is active. 
 
If you already know the weight to be tared, you can also type it in manually. To do so, press SHIFT and 
TARE on the remote at the same time. The display now shows [0000.0].  
Use ZERO and CLR to increase/decrease the selected digit and TARE to go to the next digit. If you typed 
in the weight correctly, press SHIFT to confirm. The display now shows the tare weight as a negative 
value and the tare indication is active, 

5.4 

Hold function 

Press the HOLD button on the remote control, to freeze the current reading on the display. Press HOLD 
again, to unfreeze the reading. 
 

 

Summary of Contents for PCE-CS

Page 1: ...upiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com ...

Page 2: ...tion 6 4 1 Dimensions 6 4 2 Display 6 4 3 Remote control 7 4 4 Battery 7 5 Operation 8 5 1 Turn the scale on off 8 5 2 Zero function 8 5 3 Tare function 8 5 4 Hold function 8 5 5 Accumulation function 9 5 6 Battery voltage 9 5 7 Brightness 9 5 8 Measuring unit 9 6 Troubleshooting 10 7 Contact 11 7 1 PCE Instruments UK 11 7 2 PCE Americas 11 ...

Page 3: ...there is a danger of explosion Please mind the maximum capacity of the scale at any point Do not exceed it In order to prevent potential hazardous situations when using heavy lifting equipment it is vital the manufacturer and the operator adhere to certain requirements When using the measuring equipment no risk must be posed to the operator The operator or the person responsible for operating the ...

Page 4: ... to be made before the use of the measuring equipment The equipment must be checked before the beginning of every workday In the course of the examination the operator must ensure that no deformations or other damages for example cracks are visible all the attachment parts are present and in good order and condition for example safety splints etc the present complete system does not conceal any ha...

Page 5: ...ltimate load 400 F S Battery type Fully sealed lead acid battery 6 V 1 Ah Battery life 50 hours Charging adaptor 9 V DC 1000 mA Remote control range 15 m Remote control battery 2 x 1 5 V AAA batteries Operating temperature 10 40 C Operating humidity 85 RH under 20 C Dimensions 264 x 206 x 745 mm Weight 30 kg 3 2 Delivery contents 1 x crane scale PCE CS 10000N incl Shackle hook and battery 1 x char...

Page 6: ...1 Dimensions A mm B mm C mm D mm H mm R mm 124 206 48 264 745 45 4 2 Display LED display Charging indication Infrared receiver ON OFF button and stable indication Measuring unit indication Tare button and tare indication Max capacity ...

Page 7: ...acid battery which can be replaced if it breaks down When fully loaded the crane scale can be operated for ca 50 hours If the display of the scale begins to blink it means that the battery voltage is low In this case please recharge the battery If the battery is not recharged the scale automatically shuts down after 1 2 hours If this happens recharge the battery before the next usage To charge the...

Page 8: ... this is the case please contact our customer support To display the current zero point press SHIFT and ZERO on the remote at the same time 5 3 Tare function To use the tare function hang a weight on the scale wait for the reading to be stable and press the TARE button on the remote control or the TARE button on the scale itself The display now shows 0 and the tare indication is active If you alre...

Page 9: ...e individual accumulations by using TARE and ZERO on the remote control Press SHIFT to return to normal weighing mode If you want to deactivate the accumulation function all accumulation data will be deleted press the CLR button on the remote control The display now shows Clr Press SHIFT to confirm the deletion or press CLR to cancel it 5 6 Battery voltage Press SHIFT and F1 on the remote at the s...

Page 10: ... customer support Load cell cable damaged Contact customer support Out of calibration range Contact customer support Display shows excessive zero drift between measurements Electronics do not stabilize after turning on After turning on let scale hang for 3 5 minutes Scale was put on the ground for too long Scale should be hung Displayed weight differs from actual weight Scale was not zeroed before...

Page 11: ...e contact PCE Instruments 7 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 7 2 PCE Americas By post PCE Americas Inc 711 Commerce Way Suite 8 Jupiter 33458 FL USA By phone 561 3209162 ...