Manual
8
5
Operation
5.1
Turn the scale on/off
To turn the crane scale on, press and hold the ON/OFF Button on the scale for 3 seconds.
Now, the display shows the following:
1. [88888]
2 times
2. [ Ert ]
2 times
3. [XXXXX]
capacity of the scale
4. [U 6.XX]
current battery voltage
5. [-----]
waiting for stable
6. [ 0]
reading is stable -> stable indication is active
Now you can measure with the crane scale.
To turn the scale off, press and hold the ON/OFF button on the scale or the OFF button on the remote for
3 seconds.
5.2
Zero function
If the scale is unloaded but the display does not show “0”, you can zero the scale manually. To do so, just
press the ZERO button on the remote control.
Note: This cannot be done, if the displayed value exceeds 4 % of the capacity of the scale. If this is the
case, please contact our customer support.
To display the current zero point, press SHIFT and ZERO on the remote at the same time.
5.3
Tare function
To use the tare function, hang a weight on the scale, wait for the reading to be stable and press the TARE
button on the remote control or the TARE button on the scale itself.
The display now shows “0” and the tare indication is active.
If you already know the weight to be tared, you can also type it in manually. To do so, press SHIFT and
TARE on the remote at the same time. The display now shows [0000.0].
Use ZERO and CLR to increase/decrease the selected digit and TARE to go to the next digit. If you typed
in the weight correctly, press SHIFT to confirm. The display now shows the tare weight as a negative
value and the tare indication is active,
5.4
Hold function
Press the HOLD button on the remote control, to freeze the current reading on the display. Press HOLD
again, to unfreeze the reading.