1  Introduction 

Thank you for purchasing a PCE-PCO 1 from PCE Instruments. 
This instrument is a universal particle counter for detecting the particles concentration in the air. The 
particle counter can measure six different particle sizes. Furthermore, the device has got sensors for 
temperature and relative humidity; this makes it a really versatile device. The integrated camera allows 
connecting the measurement data with image / video material. This particle counter is designed to 
accurately determine the degree of air contamination. The pollution is caused mainly by combustion, 
industrial manufacturing, power generation, vehicle engine emissions and the construction industry. With 
the help of this device the exact amount of dirt particles in the air is measured. 

2  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damages or injuries caused by non-observance of the manual.

 

 
- The device may only be used in the approved temperature range. 

The case should only be opened by qualified personnel of PCE Instruments. 

 

- The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a 
  table).  
- You should not make any technical changes to the device. 
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner. Do not use 
  abrasives or solvent based cleaners. 
- If the device is not used for an extended period, please remove the batteries. 
- This device may only be used in the way described in this manual. If the device is used otherwise, this 
  may lead to dangerous situations. 
- Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 
- Never use the device with wet hands.  
- The device may only be used with optional accessories offered by PCE Instruments or equivalent 
  substitutes. 
- Please check the housing for visual signs of damage before each use. If any visible damage occurs, the 
  device must not be used. 
- In addition, this device must not be used if the ambient conditions (temperature, humidity ...) are not 
  within the limits stated in the specifications. 
- The device must not be used in an explosive atmosphere. 
- If the safety instructions are not followed, it may cause damage to the device and injury to the operator.

 

 
This user's handbook is published by PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms which can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Summary of Contents for PCE-PCO 1

Page 1: ...Jupiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Bu...

Page 2: ...7 5 3 2 Start Delay 7 5 3 3 Channel Display 7 5 3 4 Environment Set 8 5 3 5 Sample Cycle 8 5 3 6 Sample Mode 8 5 3 7 Interval 9 5 3 8 Level Indication 9 5 4 File Browser 9 5 5 System Set 9 5 5 1 Date...

Page 3: ...rument should never be placed with the user interface facing an object e g keyboard side on a table You should not make any technical changes to the device The appliance should only be cleaned with a...

Page 4: ...r ft Counting efficiency 50 at 0 3 m 100 with particle size 0 45 m Data storage 5000 records Counting modes cumulative differential concentration Air temperature and humidity Air temperature Measuring...

Page 5: ...On Off button 9 Particle sensor 10 Temp RH sensor 11 Camera sensor 12 CO Sensor 13 USB Interface 14 AC DC connection 15 HCHO Sensor 16 Battery compartment 4 1 Switching on off To turn the device on ho...

Page 6: ...to start the particle measurement The measurement ends automatically after the preset measurement duration alternatively you can stop the measurement with the Start Stop button any time After completi...

Page 7: ...Time Start the input with Enter Use the arrow keys to adjust the measurement time Confirm your entry with Enter 5 3 2 Start Delay Start the input with Enter Use the arrows to adjust the start delay Co...

Page 8: ...1 Sample modes explanation Cumulative and differential The recorded numbers of particles are added up per channel cumulative starting with the largest channel In differential mode there are the absolu...

Page 9: ...the selected particle sizes 5 4 File Browser Press F1 while you are in the home screen to open the file browser There are the following subcategories Picture Video and Particle Logs in the file browse...

Page 10: ...remaining memory capacity of the memory card Factory Setting Reset the device to factory defaults Units C F Switch temperature units 5 5 1 Date Time Set the value with the help of the arrow Press Ente...

Page 11: ...e automatic display timeout Select Disable to switch off the function Press ESC to save the settings and exit the menu 5 5 7 Alarm Select Use the arrow to switch the alarm function on off Select Disab...

Page 12: ...s ESC to save the settings and exit the menu 6 Cleaning In order to clean the device unscrew the standard head Now attach the zero filter and carry out a cumulative measurement in measurement mode If...

Page 13: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 8 Contact If you have any questions about our rang...

Reviews: