background image

4-2 Data Hold

* During the measurement, press the " Hold Button "

( 3-4, Fig. 1 ) momentarily to hold the measured

value. The LCD  will show a  " HOLD " symbol.

* Press the" Hold Button " once again to release the

data hold function.

4-3 Data Record ( Max., Min. reading )

1)The data record function records the maximum and

minimum readings. Press the " REC Button " ( 3-5, Fig.

1 ) momentarily to start the Data Record function,

shows  " REC " on the display.

2)With the " REC " symbol on the display.

a)Press the " REC Button " ( 3-5, Fig. 1 ) momentarily,

the  " REC MAX " symbol along with the maximum

value will appear on the display.

b)Press the " REC Button " ( 3-5, Fig. 1 ) momentarily

again, the  " REC MIN " symbol along with the

minimum value will appear on the display.

* When display shows " REC MAX  " or " REC MIN ",

press the " Hold Button " ( 3-4, Fig. 1 )

momentarily will delete the max. ( min. ) value, 

the display will show the " REC. " only and

execute the  memory function continuously.

c) To exit the memory record function, press the  

" REC " button for 2 seconds at least. The display will

revert to the current reading, not show " REC "

5

Summary of Contents for PCE-SMM 1

Page 1: ...niques are developed Please read the following instructions carefully and always keep this manual within easy reach PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL 33458 USA From outside US 1 Tel...

Page 2: ...moisture Probe 3 3 2 Moisture Sensing Head 3 3 3 Power Button 3 3 4 Hold Button 3 3 5 REC Button 3 3 6 LCD Display 3 3 7 Battery Compartment Cover 3 4 MEASURING PROCEDURE 4 4 1 Measurement by selecti...

Page 3: ...accuracy and provides special functions and features Operates from DC 1 5V UM4 AAA x 4 PCs batteries Built in low battery indicator Durable long lasting components enclosed in strong compact ABS plas...

Page 4: ...display reading Sampling Time Approx 0 8 second Operating 0 to 50 Temperature Operating Less than 80 R H Humidity Power Supply DC 1 5 V battery UM4 AAA x 4 PCs Power Current Approx DC 12 mA Weight 267...

Page 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 Soil moisture Probe 3 2 Moisture Sensing Head 3 3 Power Button 3 4 Hold Button 3 5 REC Button 3 6 LCD Display 3 7 Battery Compartment Cover 3...

Page 6: ...urn off the meter 2 Insert the Moisture sensing head 3 2 Fig 1 into the measured soil It is recommended that probe head should be inserted into the soil at least 10 cm when make the measurement Soil m...

Page 7: ...th the REC symbol on the display a Press the REC Button 3 5 Fig 1 momentarily the REC MAX symbol along with the maximum value will appear on the display b Press the REC Button 3 5 Fig 1 momentarily ag...

Page 8: ...eft corner of the LCD displays the low battery icon using 4 fresh 1 5 V UM4 AAA batteries To change the batteries open rotate clockwise direction the Battery Cover 3 7 Fig 1 Make sure the Battery cove...