background image

 

 

 

4. 

NAME OF PARTS AND POSITIONS   

 

 

Red Green LED 

 

Green Red LED 

 

Button: turn on/off the Datalogger 

 

Direction indication of 3-axis 

 

 

LED FLASH INDICATION   

LEDs 

Meaning 

Action 

 

 

ALM    REG 

O

         

O

 

No LEDs flash 

-No logging started 

-No battery fitted 

-Battery completely 

discharged 

Fit Battery 

 

Data 

won’t 

lose. 

Replace  battery  and 

download data 

Summary of Contents for PCE-VD 3

Page 1: ...l 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampt...

Page 2: ...be performed by qualified personnel Periodically wipe the case with a dry cloth Do not use solvents or eradicator on this instrument Safety symbols Comply with EMC 2 FUNCTIONS DESCRIPTION This datalo...

Page 3: ...he datalogger will record the time when freefall happens besides normal acceleration data 3 Specification Acceleration Sensor MEMS Semiconductor Acceleration Range 18g Acceleration Resolution 0 00625g...

Page 4: ...midity 10 C 60 C 10 RH 75 RH Dimension The pedestal 106mm x 56mm x 33 5mm The datalogger 95mm x 28mm x 21mm System Requirement Windows 2000 or Windows XP or Vista Windows 7 8 10 Minimum hardware requi...

Page 5: ...Button turn on off the Datalogger Direction indication of 3 axis LED FLASH INDICATION LEDs Meaning Action ALM REG O O No LEDs flash No logging started No battery fitted Battery completely discharged F...

Page 6: ...ttery and download data ALM REG Red and Green single flash every 60 sec Logger memory full Download data 5 OPERATING INSTRUCTIONS 1 Setup the DataLogger by software before use it 2 Under the Manual mo...

Page 7: ...untill Red LED sequencly flash four times and then logging will stop or connect the datalogger to the host and download the data the datalogger will stop automaticlly 9 DataLogger data can be read tim...

Page 8: ...l Fix the pedestal with three Screws if screws is permitted in your application this way will be preferable 2 Glue Install Fix the pedestal with glue wait for the pedestal is tightly sticked to the ob...

Page 9: ...g sampling interval 5 You have to setup the DataLogger by software before use it 6 For the affection of gravity You have to start the logger after fix the logger tightly to the object otherwise the th...

Page 10: ...rivers you can run the Vibration Datalogger software and communicate with the meter 5 Double click the icon to start the software Click on the icon on the menu bar The Setup window will appear as show...

Page 11: ...ion Free fall Detection field can be set for detecting Free fall events or not The Manual and Automatic select buttons allows the user to start data logging immediately when exit the Setup window Auto...

Page 12: ...ct the DATA LOGGER to the USB port B Open the Datalogger software program if it is not still running C Click the Download icon D The Window shown below will appear Click DOWNLOAD to begin transferring...

Page 13: ...e data from the DATA LOGGER First Setup the sampling rate and sample data points then click RUN to start reading 8 Reading for FFT Analysis Click icon to read real time spectral data for FFT analysis...

Page 14: ...ency domain graph The software computes real time spectral data using an FFT from 0 to 256 HZ The frequency of the max magnitude will be showed on this panel 9 Please view the Help file for specific a...

Reviews: