ENGLISH
11
Tightening torque:
Housing screw
Strain relief
Contact screw
Ncm
180
80
80
OUT
IN
Assembly:
• When connecting the device, pay attention to the designation
“IN”
(input or mains
side) and
“OUT”
(output or consumer side) as well as on the arrow direction inside
the electronics cover.
• Codes/Standards DIN VDE 0661 and DGUV Information 203-006 (former BGI/GUV-I 608)
• Only use household plugs and connectors (VDE 0620) or industrial plugs and connec-
tors 16A 3p 6h (IEC/EN 60309-2)!
• Strain relief: Install clamp in the correct position depending of the cable diameter!
Clamp
position with
cable 3G1mm²
Clamp position
with cable
3G1,5-2,5 mm²
Connection cable
H05BQ-F
H07BQ-F
H07RN-F
Connection cross-section
3G1,0 mm²
3G1,5 mm²
3G2,5 mm²
Stripping length
35 mm
Wire stripping length
7 mm
cable diameter
Ø
7,3 - 14 mm
Length connection cable
1,5m +10% before protective device
min. 1,5m after protective device