4
Installation
ALL THREE PHASE AND VARIABLE SPEED DRIVE CONNECTIONS SHOULD BE PERFORMED BY A LICENSE
PROFESSIONAL. ALL ELECTRICAL REPAIRS SHOULD BE PERFORMED BY LICENSED PROFESSIONALS.
DEBURR-IT! ASSUMES NO RESPONSIBILITY TO ANY PROPERTY OR HUMAN BODY DAMAGES IF ANY
MODIFICATIONS ARE DONE TO THE ELECTRICAL SUPPLY. BY PURCHASING THIS UNIT AND ATTEMPTING TO
INSTALL, BUYER AGREES TO THESE TERMS.
Choose a stable stand or table to run your belt sander on. Universal pedestal stands offer the most flexibility
and allows the sander to be used to its maximum potential. If you do not have a stand picked out yet, DeBurr-
It! manufactures stands for specifically for its sander.
Lag the stand firmly to the ground or attach the base of the motor securely to a heavy duty table using 5/16-
18 bolts, washers and lock nuts of a minimum of grade 5 hardware.
Single Phase – Plug the unit into a grounded 115v outlet. The receptacle and circuit current rating should be
rated for 15A minimum.
Three Phase – Connect the three power conductors of the whip to DOL magnetic starter with overloads sized
accordingly. Connect the ground to the ground lug.
VFD – All VFD units have three phase motors. Connect the three power conductors to the T1, T2, T3 terminals
on the drive. Connect incoming power to L1, L2, L3. A ground conductor MUST be ran from the motor to the
drive and from the drive to the building ground to reduce electrical noise. Refer to our VFD setup manual for
settings and control wiring.