Raise and decrease their value by pressing the
“REC”- or the “°C/F”-button, unit the correct
day is indicated.
-
Confirm your selection by pressing the
“REL”-button. Now the two ciphers on the left will be
blinking.
-
Now you can set the hour by pressing the
“REC” or the “°C/F”-button, until you have the
correct day.
-
Confirm your selection with the
“REL”-button. Now the two ciphers on the left will be blinking.
-
Raise and decrease the value, by pressing the
“REC”- or the “°C/F”- button, until you have
selected the right hour (24-hours format).
-
Confirm your setting with the
“REL”-button. Now the minute (ciphers on the right) will be
blinking.
-
Raise and decrease their value by pressing the
“REC” or the “°C/F”-button, until you have
selected the correct minute.
-
Confirm the selection by pressing the
“REL”- button. Date and time are now set.
Note
: By holding the
“REC”- key pressed, or the “°C/F”-key, the value will be changing faster.
5.13 Change the memory interval
The interval determines how often the thermometer saves the measured values.
-
Therefore keep the
“MIN/MAX”-button pressed, while turning on the device. Thus you will
access the setup mode.
-
Now press the
“HOLD”-button to access the settings of the memory interval. The two ciphers
on the left will now be blinking.
-
Raise or decrease the value, by pressing the
“REC”- or the “°C/F”-button until it shows the
desired value for the hour (24-hours format).
-
Confirm by pressing the
“REL”-button. Now the two ciphers on the right will be blinking.
-
Raise or decrease the indicated value by pressing the
“REC”- or the “ON/OFF”-button, until
the correct value for the minutes is indicated.
-
Confirm your choice by pressing the
“REL”- button. Now the interval is set.
Note
: By keeping the
“REC”- or the “°C/F”- button pressed, the value can be changed faster.
5.14 Erase memory
If the device
’s internal memory is full, the display will indicate a blinking “REC”-symbol. This means
that the values will be no longer recorded.
In order to erase the memory:
-
Keep the
“REC”-button pressed and turn on the device in order to switch to the “erase”-
mode.
-
The device will now start a countdown, which will be indicated on the display, starting at 5
seconds. This is a safety mechanism. If you do not want to erase the data, release the
“REC”-button, before the countdown reaches 0.
5.15 Calibrating the device
-
Place the sensor in a known, stable temperature area.
-
Wait until the measurement value is stable. Now you have the option to alternate the Offset-
value in the setup-menu, until it is accordant to the actual temperature (reference value).
-
Turn on the device while keeping the
“REL” or the “HOLD”- button pressed to access the set-
up mode.
-
Press within three seconds the
“°C/F”-button, and then the “Hold” button to access the
calibration mode.