background image

 

Manual 

 

                                                                                                                                     

www.industrisal-needs.com

 

 

 

Raise and decrease their value by pressing the 

“REC”- or the “°C/F”-button, unit the correct 

day is indicated.  

Confirm your selection by pressing the 

“REL”-button. Now the two ciphers on the left will be 

blinking. 

Now  you  can  set  the  hour  by  pressing  the 

“REC”  or  the  “°C/F”-button,  until  you  have  the 

correct day. 

Confirm your selection with the 

“REL”-button. Now the two ciphers on the left will be blinking.  

Raise and decrease the value, by pressing the 

“REC”- or the “°C/F”- button, until you have 

selected the right hour (24-hours format). 

Confirm  your  setting  with  the 

“REL”-button.  Now  the  minute  (ciphers  on  the  right)  will  be 

blinking. 

Raise  and  decrease  their  value  by  pressing  the 

“REC” or the  “°C/F”-button, until you have 

selected the correct minute. 

Confirm the selection by pressing the 

“REL”- button. Date and time are now set.  

 

Note

: By holding the 

“REC”- key pressed, or the “°C/F”-key, the value will be changing faster.  

5.13  Change the memory interval 

The interval determines how often the thermometer saves the measured values. 

Therefore  keep  the 

“MIN/MAX”-button  pressed,  while  turning  on  the  device.  Thus  you  will 

access the setup mode.  

Now press the 

“HOLD”-button to access the settings of the memory interval. The two ciphers 

on the left will now be blinking. 

Raise or decrease the value, by pressing the 

“REC”- or the “°C/F”-button until it shows the 

desired value for the hour (24-hours format).  

Confirm by pressing the 

“REL”-button. Now the two ciphers on the right will be blinking.  

Raise or decrease the indicated value by pressing the 

“REC”- or the “ON/OFF”-button, until 

the correct value for the minutes is indicated. 

Confirm your choice by pressing the 

“REL”- button. Now the interval is set. 

Note

: By keeping the 

“REC”- or the “°C/F”- button pressed, the value can be changed faster.  

5.14  Erase memory 

If the device

’s internal memory is full, the display will indicate a blinking “REC”-symbol. This means 

that the values will be no longer recorded.  
In order to erase the memory: 

Keep  the 

“REC”-button  pressed  and  turn  on  the  device  in  order  to  switch  to  the  “erase”-

mode.  

The device  will  now  start a  countdown,  which  will be  indicated  on  the  display,  starting  at  5 
seconds.  This  is  a  safety  mechanism.  If  you  do  not  want  to  erase  the  data,  release  the 
“REC”-button, before the countdown reaches 0.  

5.15  Calibrating the device 

Place the sensor in a known, stable temperature area.  

Wait until the measurement value is stable. Now you have the option to alternate the Offset-
value in the setup-menu, until it is accordant to the actual temperature (reference value).  

Turn on the device while keeping the 

“REL” or the “HOLD”- button pressed to access the set-

up mode.  

Press  within  three  seconds  the 

“°C/F”-button,  and  then  the  “Hold”  button  to  access  the 

calibration mode.  

Summary of Contents for PCE-HPT 1

Page 1: ...n 1 0 16 09 2014 www industrial needs com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southhampton Hampshire United Kingdom SO31 4RF Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info industrial needs com www industrial needs com ...

Page 2: ...Switch temperature unit 6 5 5 Data Hold function 6 5 6 Display lights 6 5 7 Deviation measurements 6 5 8 Data recording 6 5 9 MAX MIN function 6 5 10 Automatic switch off 6 5 11 Indication of the battery state 6 5 12 Set time and date 6 5 13 Change the memory interval 7 5 14 Erase memory 7 5 15 Calibrating the device 7 5 16 Return to initial settings 8 6 Data transfer to a computer 8 6 1 Installin...

Page 3: ...urther evaluations of the captured data Furthermore the measurement results are shown with real time speed The internal clock with time and date facilitates an accurate correlation of the measured data The microprocessor thermometer features an internal data logger with an adjustable measurement interval 1 1 Delivery Content 1 x microprocessor thermometer PCE HPT 1 1 x PT 100 sensor 1 x USB cable ...

Page 4: ...ted The device cannot be used in explosion hazardous areas The threshold specified in this manual cannot be trespassed under any circumstance Do not use the device if the battery is down e g the display indicates that the battery is low since it might lead to wrong measurement results First change the batteries before operating the device again Please check the measurement device prior to every op...

Page 5: ...splay lights 4 Button for deviation measurement REL 5 Button for data recording REC 6 Key for MIN MAX function MIN MAX 7 Key for Data Hold function HOLD 8 Switch for temperature unit C F 9 Interface for connection to computer 10 Input for optional adapter 11 Stand 12 Cover of battery compartment 4 1 Pins of connection socket for temperature sensor ...

Page 6: ...d of the metal tube of the measurement sensor In order to achieve an accurate measurement of internal temperatures insert the sensor head deep into the medium which should equal at least fifteen times the sensor diameter Symbol Explanation The battery state is low No precise operation MIN Indicating minimum value MAX Indicating maximum value HOLD The data HOLD function is activated The function au...

Page 7: ...s the REC key again 5 9 MAX MIN function By pressing the MIN MAX button once you will access the MAX MIN function This mode indicates the relevant maximum and minimum value at the display If the display indicates MAX the maximum value will be indicated By pressing the MIN MAX key again the display switches to the minimum values The display will then indicate MIN By pressing the MIN MAX button agai...

Page 8: ...ng Raise or decrease the value by pressing the REC or the C F button until it shows the desired value for the hour 24 hours format Confirm by pressing the REL button Now the two ciphers on the right will be blinking Raise or decrease the indicated value by pressing the REC or the ON OFF button until the correct value for the minutes is indicated Confirm your choice by pressing the REL button Now t...

Page 9: ...e the function Default factory setting value Confirm with pressing the HOLD key again Note You can cancel the process at any time by pressing the Power button 6 Data transfer to a computer 6 1 Installing the software The enclosed CD will contain the software for the data collection as well as a USD driver for the device The software is compatible with the following system software Windows NT 4 0 N...

Page 10: ...ce manager under the system settings to see under which COM Port the device is listed e g the example below is the COM4 Port After completing the installation the device can be connected via its USB cable to a computer Start the software and select the correct COM Port in the Drop Down menu ...

Page 11: ...in minutes and seconds You can save up to 5000 data points In case of transgression the oldest 100 points will be overwritten Option Here you can find the options to alternate the parameters of the graph 6 3 Real time graph Within the graph you can zoom in by pressing the left mouse button and marking an image section and then releasing To revoke the zoom again click on the Undo Zoom button 6 4 Ta...

Page 12: ... data logger Thus a progress beam will indicate the state of the data transfer After a successful transfer of the data the number of transferred data sets will be indicated at the left side of the display with their parameters time and date of start sampling rate Each data set can be seen in detail as a diagram or a data table by clicking ...

Page 13: ...oth made of cotton that makes no fluffs If necessary use a mild cleaner Do not use any abrasive detergent or chemical solution 8 Disposal Batteries may not be put in the household waste They have to be given in the set up collection points NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases Please contact PCE Instru...

Reviews: