5.2. Functions of the button
The device contains one physical button for restoring the factory settings or
displaying the current IP address of the monitor. This button is located on the connector
panel –
fig. 3
.
-
restoring factory parameters
- after pressing and holding the button for 10 seconds;
Note:
each successive restoring of factory parameters enables or disables the service of
obtaining network address from a DHCP server, i.e. if the DHCP service is enabled and
restoring the factory parameters will be forced , the DHCP service will be disabled (you will
be informed about the change by a message on the display) and default static IP address
will be assigned to the device: 192.168.1.19 (subnet mask: 255.255.255.0), another
request for restoring the factory parameters will enable the DHCP server service -
the network parameters will be obtained dynamically from the server;
-
displaying the current IP address of the monitor
– occurs after a short press