background image

 

 

 

©  PCE Instruments 

12 

 

10  Warranty 

You  can  read  our  warranty  terms  in  our  General  Business  Terms  which  you  can  find  here: 

https://www.pce-instruments.com/english/terms

 

11  Disposal 

For  the  disposal  of  batteries  in  the  EU,  the  2006/66/EC

 

directive  of  the  European  Parliament 

applies. Due to the contained pollutants, batteries must not be disposed of as household waste. 
They must be given to collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use 
them or give them to a recycling company which disposes of the devices in line with law. 
 
For  countries  outside  the EU,  batteries  and  devices  should  be  disposed  of  in accordance  with 
your local waste regulations. 
 
If you have any questions, please contact PCE Instruments. 
 

 

 
 
 
 

 

Summary of Contents for PCE-VMM 100

Page 1: ...PCE VMM 100 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 8...

Page 2: ...ntents 1 Safety notes 1 2 Technical specifications 2 3 Delivery contents 2 4 Device description 3 5 Start up 6 6 Control menu description 7 7 Operation 10 8 Troubleshooting 11 9 Cleaning 11 10 Warrant...

Page 3: ...om PCE Instruments or equivalent If the wrong mains adaptor is used fire or electric shocks can occur Before each use inspect the case for visible damage If any damage is visible do not use the device...

Page 4: ...e rate 60 fps Camera functions Autofocus image and video recording HDMI output White balance brightness control digital noise reduction Microscope stand Z axis travel 100 mm coarse lifting via focusin...

Page 5: ...ruments 3 4 Device description Front view 1 Microscope camera 7 Coarse drive 2 Magnification 8 Light adjustment knob 3 Light source 9 Bracket 4 Specimen stage 10 Microscope stand 5 Base 11 Housing 6 A...

Page 6: ...PCE Instruments 4 Rear view 1 HDMI port 4 DC 5 V 2 Memory card slot 5 DC 12 V 3 USB port...

Page 7: ...PCE Instruments 5 Bottom view 1 HDMI port 2 USB port...

Page 8: ...men on platform and adjust the light Focusing Dimming Magnification Turn the focusing knob for focusing Adjust the brightness of the light source by turning the knob Turn the magnification adjustment...

Page 9: ...tal vertical Set Save settings Exposure AE Automatic exposure adjustment of brightness ME Manual exposure adjustment of gain Color AWB Automatic white balance MWB Manual white balance adjustment of RG...

Page 10: ...wo lines Hor Ver The lines can be displayed or hidden Set the line position by moving the slide bar Click on one of the color patches to change the color There are nine colors to choose from Default D...

Page 11: ...PCE Instruments 9 Click Edit Time to select the date on the left hand side and the time on the right hand side Then confirm by clicking Save Time...

Page 12: ...e correct white balance target a pure white object with the camera such as the white standard that comes with the microscope and set the exposure mode to AE With the MWB function you can adjust the RG...

Page 13: ...perly connected Check the VGA cable connection 5 Stiff focus adjustment Focusing knob locked too tightly Loosen focusing knob slightly In case of any other problem please contact PCE Instruments 9 Cle...

Page 14: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 15: ...dustrial needs com info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands Chile Hong Kong PCE Brookhuis B V PCE Instruments...

Reviews: